NeoClock
page 14
APPENDIX A
CONTROL CODES
The operation mode of NeoClock can be to configured using following
ASCII control codes:
Selecting the mode
"8"
transmission of the data string in binary mode
"9"
transmission of the data string in ASCII mode
"N"
select the binary data string as shown in table 2
(with header indicating the antenna system in use and time string
with hundreds of seconds)
Selecting the data output rate
"A"
automatic transmission of 1 data string / second
"E"
automatic transmission of 1 data string / minute
"@"
transmission of the data string only on request
Serial number
"$"
ask for the serial number of the receiver (6 bytes).
Firmware Version
"V"
firmware version and copyright