Automatic operation with optional dwell cable 

NOTE: 

Optional accessory (not included in the complete set)

1.  To protect the unit and the animal, ElectroJac 6 must be prepared for use prior to 

beginning the operation. To prepare the unit: 
a.  Set the

 Auto/manual 

switch on the electronics instrument case to 

Auto

b.   Set the 

On/off 

switch on the dwell control box to 

Off

c.   Set the 

Manual

 control on the electronics instrument case to 

Low

.

d.  Plug one end of the probe cable into the electronics instrument case in the port 

marked 

Probe

 (on the case’s right side) and the other end to the probe.

e.   Plug the dwell cable into the electronics instrument case in the port marked 

Dwell

 

(on the case’s left side).

 

2.  Once the animal is prepared for collection, insert the probe into the animal’s rectum 

with the three brass electrodes facing down.

3.  After the probe is in place, set the 

On/off 

switch on the dwell control box to 

On

.  

ElectroJac 6 will automatically start through 40 cycles (2 seconds on, 2 seconds off) 
unless the 

Dwell

 switch is held down.

4.  The red dwell light will glow and the numeric display will indicate the progression 

through the unit’s 40 cycles. A glowing dot in the bottom right-hand corner of the display 
indicates when power is being delivered to the probe. Once semen collection is com-
pleted, turn the 

On/off 

switch to 

Off

.

5.  After use, wipe the probe and cables down with a sponge and a nontoxic, nonabrasive 

cleaning solution.

 

Resetting the unit

If the animal experiences extreme discomfort, the unit may be reset to the lowest power 
level at any time by simply setting the 

On/off

 switch to 

Off

. When the unit is turned back on, 

it will automatically reset to the lowest power level.

Using the dwell switch

When the dwell switch is pressed, the electronics will remain at the current cycle, and 
continue to repeat that power level. When released, it will continue to cycle, starting at the 
next power level. 

Example

When the animal becomes stimulated, the dwell 
button may be depressed. By holding the switch 
down, the unit will remain at that level until 
ejaculation. Should the animal appear to lose 
stimulation, release the switch and the unit will 
automatically continue increasing the intensity 
of each cycle until the animal again becomes 
stimulated.

Dwell light

Dwell switch

On/off switch on 

dwell control box

Содержание Electro Jac 6

Страница 1: ...Operator s Manual...

Страница 2: ......

Страница 3: ...operation with optional dwell cable 7 Manual operation with wireless remote control 8 Manual operation with optional dwell cable 9 Troubleshooting 10 Frequently asked questions 11 Battery and AC batte...

Страница 4: ...ri narians spread a bucket of sand over the enclosure s floor to increase a bull s footing and others have bulls stand in ankle deep sand to ensure stable footing 3 Prestimulate the bull Manually pres...

Страница 5: ...handling the optional dwell box The on off switch and the dwell switch can be damaged if the box is not handled with care 5 After inserting the probe hold the bull s tail down to prevent the probe fr...

Страница 6: ...Probe cable assembly 6901 Carrying case 6992 2 5 64 mm Bull probe 15 5 394 mm length 4 75 lbs 6993 3 76 mm Bull probe 15 5 394 mm length 6 25 lbs 6902 Replacement battery And your choice of probe siz...

Страница 7: ...er the on off button or the dwell button Manual operation In manual mode the intensity is con trolled by adjusting the manual control Increasing voltage is applied to the probe s electrodes as the man...

Страница 8: ...the red button on remote control for 2 seconds 5 After use wipe the probe and cables down with a sponge and a nontoxic nonabrasive cleaning solution Resetting the unit If the animal experiences extrem...

Страница 9: ...4 The red dwell light will glow and the numeric display will indicate the progression through the unit s 40 cycles A glowing dot in the bottom right hand corner of the display indicates when power is...

Страница 10: ...To prepare the unit a Set the Auto manual switch on the electronics instrument case to Manual b Set the Manual control on the electronics instrument case to Low c Plug one end of the probe cable to t...

Страница 11: ...ac 6 must be prepared for use prior to beginning the operation To prepare the unit a Set the Auto manual switch on the electronics instrument case to Manual b Set the On off switch on the dwell contro...

Страница 12: ...the unit is charging d If the charging circuit needs to be replaced call 800 621 8829 for technical support 4 What do I do if moisture gets in the unit If moisture gets in the unit allow the unit to d...

Страница 13: ...ble 7 If needed would you send me drawings so I can repair the unit myself No due to legalities and to ensure proper operation and maintain the warranty only an authorized repair facility may repair E...

Страница 14: ...he bottom from the electronics case by opening the latches on both sides of the case while carefully sup porting the relatively heavy case bottom 2 Remove red and black leads from the battery by pulli...

Страница 15: ...returned freight prepaid Warranty ElectroJac 6 s fuse is located above the battery in the battery compart ment Fuse replacement 1 Remove the dwell cable if used and the probe cable 2 Unlatch the batte...

Страница 16: ...Neogen Corporation 2012 Ideal and ElectroJac are registered trademarks of Neogen Corporation Lansing MI 48912 L2429 0112 800 621 8829 or 859 254 1221 www neogen com...

Отзывы: