6
Automatic operation with wireless remote control
1. To protect the unit and the animal, ElectroJac 6 must be prepared for use prior to
beginning the operation. To prepare the unit:
a. Set the
Auto/manual
switch on the electronics instrument case to
Auto
.
b. Set the
Manual
control on the electronics instrument case to
Low
.
2. Once the animal is prepared for collection, insert the probe into the animal’s rectum
with the three brass electrodes facing down.
3. After the probe is in place, press the green button on the remote control. ElectroJac
6 automatically will start through 40 cycles (2 seconds on, 2 seconds off) unless the
dwell button is held down.
4. A glowing dot in the bottom right-hand corner of the display indicates when power is be-
ing delivered to the probe. Once semen collection is completed, press and hold the red
button on remote control for
2 seconds
.
5. After use, wipe the probe and cables down with a sponge and a nontoxic, nonabrasive
cleaning solution.
Resetting the unit
If the animal experiences extreme discomfort, the unit may be reset to the lowest power
level at any time by simply pressing the red button on the remote and holding for 2 seconds.
When the unit is turned back on, it will automatically reset to the lowest power level.
Using the dwell button
When the dwell button is pressed, the electronics will remain at the current cycle, and
continue to repeat that power level. When released, it will continue to cycle, starting at the
next power level.
Example
When the animal becomes stimulated, holding the dwell button down will allow the unit to
remain at that level until ejaculation. Should the animal appear to lose stimulation, release
the switch and the unit will automatically continue increasing the intensity of each cycle
until the animal again becomes stimulated.