background image

Inclusion/Exclusion 

On factory default the device does not belong to any Z-Wave network. The device needs to be 

added 

to an existing wireless network

 to communicate with the devices of this network. This process is 

called 

Inclusion

Devices can also be removed from a network. This process is called 

Exclusion

. Both processes are 

initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion 
respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action 
right on the device. 

Inclusion 

Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will 
flash on and off alternately five times. 

Exclusion 

Press the button three times within 1.5 second, the device will enter exclusion mode. 

Product Usage 

Battery life of door sensor is approximately 2 years. The power level of battery would be displayed in 
the gateway. Red icon means the battery needs replacing, and then mobile app would receive a 
message “power level is low, please remember to replace battery” from gateway. In order to avoid 
false alarm, before replacing battery, please disconnect association of door sensor with other devices. 

Note: 

Door sensor is powered by battery, and please use battery in a correct way to avoid exploding. 

When handling the battery, refer to environmental law please. 

1. When door sensor is triggered, LED lights would flash red colour 1 time. 
2. When door sensor is installed with battery, LED lights would flash red colour 5 times. 
3. Add or remove door sensor from Z-Wave network by quickly pressing the button 3 times, then LED 
lights would flash red colour 5 times. 
4. Press and hold the code button for 10-15s, then door sensor would be restored to factory default 
settings. Meanwhile, LED lights would flash red colour 5 times on and off alternately. 
5. Under the normal state, LED lights would keep “off “ state. 
 

Communication to a Sleeping device (Wakeup) 

This device is battery operated and turned into deep sleep state most of the time to save battery life 
time. Communication with the device is limited. In order to communicate with the device, a static 
controller 

C

 is needed in the network. This controller will maintain a mailbox for the battery operated 

devices and store commands that cannot be received during deep sleep state. Without such a 
controller, communication may become impossible and/or the battery life time is significantly 
decreased. 

This device will wake up regularly and announce the wakeup state by sending out a so called Wakeup 
Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured 
with the desired wakeup interval and the node ID of the controller. If the device was included by a 
static controller this controller will usually perform all necessary configurations. The wakeup interval is 
a tradeoff between maximal battery life time and the desired responses of the device. To wake up the 
device please perform the following action: Manual Wakeup the Sensor You can press the button 
once to wake up the device and send wakeup notification to controller. If press successfully, the LED 
will blink one time. 

Quick trouble shooting 

Here are a few hints for network installation if things don

’t work as expected. 

1.  Make sure a device is in factory reset state before including. In doubt exclude before include. 
2.  If inclusion still fails, check if both devices use the same frequency. 
3.  Remove all dead devices from associations. Otherwise you will see severe delays. 
4.  Never use sleeping battery devices without a central controller. 

Содержание NEOEDS01Z

Страница 1: ...ke sure the internal battery is fully charged 1 Remove the sensor cover 2 Make sure the sensor is powered 3 Set Z Wave controller or Z Wave gateway into inclusion mode Refer to the controller or gatew...

Страница 2: ...applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network In the front casing there is button that is used to ca...

Страница 3: ...installing door sensor door sensor deputy body must be installed on the bulge side of the door sensor main body 1 When install door sensor the distance between main body and deputy body should be les...

Страница 4: ...or 10 15s then door sensor would be restored to factory default settings Meanwhile LED lights would flash red colour 5 times on and off alternately 5 Under the normal state LED lights would keep off s...

Страница 5: ...ugh the advanced parameters no 1 and 2 This Group Support BASIC_SET 3 5 GROUP 3 allows for Send Notification to associated devices in this group This Group Support NOTIFICATION_REPORT 4 5 GROUP 4 allo...

Страница 6: ...tion Sensor Network Operation Reporting Sleeping Slave Z Wave Version 6 51 06 Certification ID ZC10 16055076 Z Wave Product Id 0x0258 0x0003 0x1082 Sensors Open Closed Binary Color White Firmware Upda...

Страница 7: ...tral organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the...

Отзывы: