Association - one device controls an other device 

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling 
another device is called association. In order to control a different device, the controlling device needs 
to maintain a list of devices that will receive controlling commands. These lists are called association 
groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case 
the event happens all devices stored in the respective association group will receive the same wireless 
command wireless command, typically a 'Basic Set' Command. 

Association Groups: 

Group 
Number 

Maximum 
Nodes 

Description 

GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector) 
status u2013 Open/Close. It enables the sensor to send reports and readings to 
Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered. This 
Group Support: NOTIFICATION_REPORT BATTERY_REPORT 
SENSOR_BINARY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION 

GROUP 2 allows for sending control commands to associated devices such as 
relay module, lighting, etc. This association group is configured through the 
advanced parameters no. 1 and 2. This Group Support: BASIC_SET. 

GROUP 3 allows for Send Notification to associated devices in this group. This 
Group Support: NOTIFICATION_REPORT 

GROUP 4 allows for Send Notification to associated devices in this group. This 
Group Support: SENSOR_BINARY_REPORT 

Configuration Parameters 

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration 
can adapt the function better to user needs or unlock further enhanced features. 

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 

128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set 
a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two 
byte value the same logic applies: Values greater than 32768 may needed to be given as negative 
values too. 

Parameter 1: Configuring the OFF Delay 
This configuration parameter can be used to adjust the amount of delay before the OFF command is 
transmitted. 

 

Size: 2 Byte, Default Value: 0 

Setting 

Description 

0 - 65535 

Seconds 

Parameter 2: Basic Set Level 
Basic Set Command will be sent where contains a value when the door/window is opened or closed, 
Z-Wave controller or z-wave gateway will take it for consideration; for instance, if a lamp module 
receives the Basic Set Command of which value is decisive as to how bright of dim level of lamp 
module shall be. 

 

 

 

 

Содержание NEOEDS01Z

Страница 1: ...ke sure the internal battery is fully charged 1 Remove the sensor cover 2 Make sure the sensor is powered 3 Set Z Wave controller or Z Wave gateway into inclusion mode Refer to the controller or gatew...

Страница 2: ...applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network In the front casing there is button that is used to ca...

Страница 3: ...installing door sensor door sensor deputy body must be installed on the bulge side of the door sensor main body 1 When install door sensor the distance between main body and deputy body should be les...

Страница 4: ...or 10 15s then door sensor would be restored to factory default settings Meanwhile LED lights would flash red colour 5 times on and off alternately 5 Under the normal state LED lights would keep off s...

Страница 5: ...ugh the advanced parameters no 1 and 2 This Group Support BASIC_SET 3 5 GROUP 3 allows for Send Notification to associated devices in this group This Group Support NOTIFICATION_REPORT 4 5 GROUP 4 allo...

Страница 6: ...tion Sensor Network Operation Reporting Sleeping Slave Z Wave Version 6 51 06 Certification ID ZC10 16055076 Z Wave Product Id 0x0258 0x0003 0x1082 Sensors Open Closed Binary Color White Firmware Upda...

Страница 7: ...tral organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the...

Отзывы: