8
MASTER KEYPAD DISPLAY SUMMARY
Indicator
Lit
Flashing
Off
ON
At least one energizer on.
All energizers are in HV
mode
Not all energizers in HV
mode
All energizers off
irrespective of voltage
setting.
GOOD
All energizers on. No
alarm condition present
Not all energizers on. No
alarm condition present
Some alarm condition
present
POWER
Mains present on all
energizers
Mains present at some
energizers
No mains present on any
energizer
FENCE
NA
Fence Alarm# NOTE^
No Fence Alarm
GATE
NA
Gate Alarm# NOTE^
No Gate Alarm
SERVICE
NA
Battery Low
on energizer # NOTE*
No service condition
COMMS
NA
Communication Failure
on energizer # NOTE *
No communication failure
condition
TAMPER
NA
Tamper Alarm
on energizer # NOTE*
No energizer lid removed
Note ^:
The Master Energizer has Fence Zones 1 and 2 and Gates 1 and 2.
The First Slave has Fence Zones 3 and 4 and Gates 3 and 4.
The Second Slave has Fence Zones 5 and 6 and Gates 5 and 6 etc
.
Note*:
The Service/Comms/Tamper indicators refer to the actual energizer address
e.g. a lid removed on the second slave would give a TAMPER 3 indication and
not a TAMPER 5 and 6 indication
.
USING KEYPADS ON INDIVIDUAL ENERGIZERS
.
If individual keypads are used on slave energizers, the keypads have full
accessibility to the energizer functions. In certain cases parameters are
written to non-volatile memory. Because this process takes an undefined
amount of time synchronization may be lost if the system is a synchronized
network. The energizer will pulse in a safe mode (low-voltage) until the
Master can detect and re-synchronize the network. This typically takes four or
five seconds.
Please note that the Master Keypad does not work on Slave units.
Refer to the Merlin Stealth User Manual for a description of the keypad
operation.
MERLIN STEALTH
MASTER
KEYPAD DISPLAY