INTRODUCTION 

 

 

1.0 Introduction 

 

The Merlin Stealth Energizer M25S Master or M28S Master enables up to ten 
energizers to be networked.  
 
The  system  user  can  send  through  the  Master  energizer  global  or  energizer 
specific  commands  to  turn  energizers  On/Off  and  change  between  High-
Voltage and Low-Voltage modes. Fence and Gate alarm indication is given for 
individual zones on the Master keypad. 
 
Familiarity  with  the  Merlin  Stealth  Energizer™  Range  will  facilitate  the 
understanding of the Master controller. 
 
Each  of  the  networked  energizers  may  have  their  own  individual  keypads 
giving access to all the programmable features of the individual energizer. For 
security  reasons,  the  individual  keypads,  can  be  disabled  by  using  a  unique 
personal identification number (PIN) on each energizer.  
 
The  lid  tamper  switches,  mains  and  battery  condition,  communication  and 
synchronization  status  of  each  energizer  is  monitored  and  displayed  once  a 
second. 
 
For safety reasons the energizers may be pulsed in a synchronized manner. 
 
Communication errors in a network can occur and it is the responsibility of the 
user  to  ensure  that  the  system  is  in  the  desired  state.  If  operating  as  a 
synchronized  network,  system  safety  is  of  paramount  importance,  and  any 
loss  of  communication  or  communication  error  will  result  in  the  affected 
network  components  defaulting  to  a  safe  operating  level.  The  Master  will 
detect  a  loss  in  synchronization  and  take  corrective  action.  The  Master  will 
periodically align the individual energizer clocks to ensure correct operation. 
 
 
 
 
 
 
 
 
 

MERLIN STEALTH

  

MASTER

       Introduction 

 

Содержание MERLIN STEALTH MASTER

Страница 1: ...Users Manual Revision 1 1 20 7 2007 GROUP OF COMPANIES MERLIN STEALTH MASTER Electric Fence Energizer...

Страница 2: ...2 MERLIN STEALTH MASTER Table of Contents FOREWORD 3 GUARANTEE 4 INTRODUCTION 5 USING YOUR MASTER KEYPAD 6 7 MASTER KEYPAD DISPLAY 8 KEYPADS ON INDIVIDUAL ENERGIZERS 8 ALARM EVENT 9 10...

Страница 3: ...M1x and M2x range Earth loop monitoring has been incorporated throughout the range onboard diagnostics communications interface RS232 and energy output and electromagnetic interference levels that com...

Страница 4: ...uth Africa OR Nemtek Security Warehouse Unit 4 Meadowdale Park Cnr Herman Dick Kemp Roads Meadowdale Edenvale Gauteng South Africa The buyer shall pay all shipping and other charges for the return of...

Страница 5: ...l keypads can be disabled by using a unique personal identification number PIN on each energizer The lid tamper switches mains and battery condition communication and synchronization status of each en...

Страница 6: ...state ON OFF TOGGLE All units Enter the Master PIN and press All the units should either be on or off Verification of all units being in the ON state is if the GOOD indicator is permanently lit Verifi...

Страница 7: ...this process seems cumbersome full status and control of individual energizers is possible with the embedded Linux platform SPECIFIC ENERGIZER ON OFF Enter your PIN master only and press the key ente...

Страница 8: ...nd 2 The First Slave has Fence Zones 3 and 4 and Gates 3 and 4 The Second Slave has Fence Zones 5 and 6 and Gates 5 and 6 etc Note The Service Comms Tamper indicators refer to the actual energizer add...

Страница 9: ...pad does not function when plugged into a slave energizer Example A six zone system comprising of a Master and Two Slaves A permanent fence fault occurs on Zone 1 of the second slave because a tree wa...

Страница 10: ...ic alarm memory condition prior to issuing this command The advantage of this method is that if the alarm condition persists on the specific energizer the alarm condition will repeat itself on the Mas...

Отзывы: