GATE ALARM DELAY TIME
1 0 _ _ * #
Sets the gate alarm delay time
m = minutes, s = x10 seconds
Programmable range is
1001*#
(10s) to
1041*#
(4min:10s)
Factory default value is
1010*#
(1min:0s)
The gate alarm will only sound once the gate has remained open for longer than the GATE
ALARM DELAY time. The GATE ALARM INSTANT user code can be used to temporarily
override this delay period, and the GATE ALARM BYPASS user code can be used to
temporarily disable the gate alarm function.
GATE CHIME ON CLOSE
1 1 9 _ * #
Enable or disable a gate close chime, only when gate chiming is enabled.
? = 0 (no chime on close) or 1 (chime on close)
Factory default value is
1190*#
(no chime on close)
The user can enable a gate chime notification using the GATE CHIME user code, as
detailed in the Druid LCD User Manual. This GATE CHIME ON CLOSE installer code
additionally enables chiming on closure of the gate as well.
INPUT TOGGLE SELECT
1 1 1 _ * #
Selects toggling or direct on/off control of the fence monitoring.
? = 0 (direct control) or 1 (toggle control)
Factory default value is
1110*#
(direct control)
With direct control, the fence monitoring is switched on when the input transitions to open
circuit. With toggle control, the fence monitoring state is toggled each time the input
transitions from closed to open circuit.
Z1 ON/OFF INPUT FUNCTION
1 1 2 _ * #
Sets the functionality of the Z1 On/Off input.
? = 0 (On/Off), 1 (panic), 2 (lock Z1 in an inactive state if input is open i.e. safety
lockout)
Factory default value is
1120
*
#
(On/Off)
m s
?
?
22
?
Programmable options