Operation without a keypad
9
Activating and deactivating the unit
Unless this feature has been disabled by the installer, the unit can be activated or
deactivated by presenting the NEMTEK plastic tab over the corresponding logo
on the fascia of the unit. Remove the tab when the unit produces a short beep,
after which the unit will toggle its operating state. The unit can also be configured
to use a remote switch.
Acknowledging and silencing an alarm condition
Present the NEMTEK plastic tab over the corresponding logo on the fascia of
the unit. An initial short beep will be heard as the tab is detected, but keep holding
the tab in place until a second longer beep is heard. The siren will be silenced if not
yet timed out, the internal beeper will stop sounding and the strobe will be
deactivated. One of the alarm
, alarm history
or event
symbols will indicate
the source of the alarm.
Clearing an alarm or event from memory
An alarm symbol indicates that the condition persists and will have to first be
corrected. An alarm history symbol indicates the fault no longer exists and
simply turning the unit off and on again, or presenting the tab until the long beep
is heard, will clear the memory condition. Only if the alarm condition is resolved will
the unit operate without alarm activation.
t
Содержание Druid LCD 20
Страница 1: ...Druid LCD 20 Fence Monitor User Manual...