Nemalux RH-20 Series Скачать руководство пользователя страница 6

Declaration Of Conformity

With The Atex Directive 2014/34/EU

& UK Directive SI 2016 No. 1107 

(as amended)

The RH series luminaire is manufactured by Raytec Ltd. for Nemalux Inc.

Raytec  Ltd.  declares  under  our  sole  responsibility  that  the  product(s)  listed  below 

conform with the relevant provisions of directive 2014/34/EU of 20

th

 April 2016 and 

UK Directive SI 2016 No. 1107 (as amended)

Compliance with the Essential Health and Safety Requirements has been assessed by 

reference to the following harmonised/designated standards -  

EN 60079-0   : 2018 

EN 60079-1   : 2014 

     EN60079-7    : 2015 + A1 2018

EN 60079-15 : 2019 

EN 60079-18 : 2015 + A1 2017 

EN60079-31  : 2014

Manufacturer

Description

of Equipment 

Certification  

Body

Certificate

numbers 

Equipment

Marking 

10

-

1

2

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

SUBJECT TO CHANGE WITHOUT NOTICE

MADE IN 

UK

11

-

1

2

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

SUBJECT TO CHANGE WITHOUT NOTICE

MADE IN 

UK

Raytec Ltd 

Unit 15, Wansbeck Business Park 

Rotary Parkway 

Ashington 

Northumberland 

NE63 8QW 

United Kingdom 

RH/

Spartan range of High Power Floodlights

CML 

New Port Road 

Ellesmere Port 

CH65 4LZ 

CML17ATEX1148 or IEC Ex CML17.0074 or CML21UKEX1102 

CML17ATEX4149 or IEC Ex CML17.0074 or CML21UKEX4101 

CML18ATEX3161 or IEC Ex CML18.0087 or CML21UKEX3107 

ATEX Quality Assurance Notification CSA BV (2813) 

UKCA Quality Assurance Notification CSA UK (0518)

II 2 GD Ex db eb mb IIB T4 Gb

Ta -50

o

C to +50

o

C

Ex tb IIIC T104°C Db

Ta -50°C to +50°C

IP66 150-264V AC/DC or 110-254V AC/DC

II 3 GD Ex nR ec IIC Gc

Ta -50

o

C to +50

o

C

Ex tb IIIC T104°C Dc

Ta -50°C to +50°C

IP66 150-264V AC/DC or 110-254V AC/DC

Ex tb IIIC T104°C Db

Ta -50°C to +50°C

IP66 150-264V AC/DC or 110-254V AC/DC

And also 2014/35/EU - Low Voltage Directive, 2014/30/EU - EMC Directive

Signed

  

Name

 

Barry Thompson 

Position 

Director

Dated

Serial number

Содержание RH-20 Series

Страница 1: ...ical Specification Trouble Shooting Important information The RH 20 25 series of explosion protected floodlights highbay are specialist devices certified for use in specific operating environments The...

Страница 2: ...ot exceed a temperature rise of 20 C above the ambient conditions select suitable cable 8 To ensure the safety of the equipment ensure that the flamepath on Zone 1 variants are free from any corrosion...

Страница 3: ...ed correctly and replace terminal block cover Tighten to 4Nm 10 If carrying out Insulation Resistance tests the normal method of insulation testing is to connect Live and Neutral together and test bet...

Страница 4: ...ove the power supply from the mains terminals then remove LED red and black wires If replacing a power supply on a Zone 2 luminaire the orange silicone gasket should be replaced at the same time to ma...

Страница 5: ...ned on at the source 4 If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by swapping LED cables to opposite power supply to help identify problem Max...

Страница 6: ...GE WITHOUT NOTICE MADE IN UK Raytec Ltd Unit 15 Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom RH Spartan range of High Power Floodlights CML New Port Road Elle...

Страница 7: ...2589 P 1 403 242 7475 F F 1 403 243 6190 E info nemalux com W www nemalux com Industrial LED Lighting designed to solve harsh and hazardous lighting challenges 12 12 www nemalux com sales nemalux com...