Control Valve Error Code Diagnosis

Under normal operating conditions, when the control valve is in the “in service” position, the display should alternate 

between the current time of day and the number of days remaining (for filters and time clock softeners) or gallons re-

maining (for metered softeners) until the next regeneration. This is the “home display.” If the valve is currently going 

through a regeneration cycle, the display will show the cycle step on the left side of the display and the number of 

minutes remaining in that step on the right side of the display. If any other information is being displayed, then the 

valve is informing you of an issue. There are five error codes which could indicate an issue with the control valve. 

When an error is being displayed, the valve will be in a stopped position, and the buttons will not respond to being 

pressed. Even if the cause of the error code is corrected, the error code will not clear until the power supply has 

been disconnected and reconnected (this will be referred to as “cycling” the power). All error codes are displayed as 

the letters “Err” followed by a flashing number 2-6:

Error 2

 - 

Valve is searching for homing slot. - 

Allow valve to continue running. If the homing slot is found, the valve 

will return to the home display, otherwise, another error code will appear.

Error 3

 - 

No encoder slots are being seen. - 

This occurs when the motor is running, but the encoder is not seeing any 

of the slots in the encoder wheel. This can happen if the encoder has been disconnected, but most commonly occurs 

when debris in the valve body has stopped the piston, causing the encoder wheel to be unable to turn.

1. Check encoder connection. If the encoder is plugged in and snapped into place, skip to step #2 below. If 

encoder is disconnected, reconnect it and cycle power to clear the error.

2. Disconnect powerhead from valve body, cycle power to clear the error code. Manually cycle the powerhead 

through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is 

disconnected from the valve body. If the error 3 does not reappear, skip to step #3 below. If the error 3 does 

reappear, order a board & motor kit to replace the circuit board & motor.

3. Remove piston and seals from the valve body and inspect valve body for debris. Replace the seal & spacer kit. 

Inspect piston and replace piston if Teflon coating is worn

Error 4 

Unable to find homing slot.

1. Check encoder wheel for debris.

2. Cycle power. Valve should either find home or go to a different error code. If error 4 returns, replace powerhead 

assembly.

Error 5

 - 

Motor overload

. - This occurs when the motor current is too high. This could be caused by an issue with the 

motor itself, but is typically caused by friction in the valve body

1. Disconnect powerhead from valve body and cycle power to clear the error code.

2. If the error 5 returns, replace the motor. Otherwise, manually cycle the powerhead through the regeneration 

cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve 

body. Either way, proceed to the next step.

3. Remove piston and seals from the valve body and inspect valve body for debris. Replace the seal and spacer kit. 

Inspect piston and replace piston if Teflon coating is worn.

Error 6

 - 

No motor current

. - This typically occurs if the motor cable has come unplugged from the circuit board. 

Check that the motor cable is plugged into the circuit board and attached to the motor. If this is not the issue, the 

motor or circuit board may need to be re-placed.

No Display

 - If your display is blank, there is no power going to the circuit board due to one of the following factors:

• The electrical outlet is not powered or is switched off.

• The power cable has come unplugged from the circuit board.

• The power supply has come unplugged from your electrical outlet.

• The power supply has come unplugged from the control valve.

• The power supply is not working.

AIO Plus Connected Series  

Error Codes

Содержание AIO Plus Connected Series

Страница 1: ...Installation Operation Manual...

Страница 2: ...th Page 6 8 Programming the Control Valve Page 9 11 Powerhead Assembly Page 12 Valve Body Assembly Page 13 Valve Body Assembly Parts List Page 14 Bypass Assembly Page 14 Service Instructions Page 15 1...

Страница 3: ...silicone grease be used as a lubricant for all control valves Dow Corning 7 Release Com pound is used in the manufacture of the control valves Part DOW 7 Sealants Pipe dope and liquid thread sealers m...

Страница 4: ...pper galvanized PVC plastic NOTE If household plumbing is galvanized and you intend to make the installation with copper or vice versa obtain dielectric unions to prevent dissimilar metal corrosion CA...

Страница 5: ...e I Replace control valve on mineral tank 3 Turn OFF main water supply and OPEN nearest faucet to relieve pressure 4 Cut main line and install appropriate elbows and extensions CAUTION Raised arrows l...

Страница 6: ...flow down through mineral tank and out the drain line Let it continue to run for the entire rapid rinse step There may be colored water or media fines during this initial flow 4 Once the rapid rinse e...

Страница 7: ...ed to be cleaned of the precipitated iron that has been collected in them or iron bleed through may be a problem We suggest all tanks be drained and flushed thoroughly Annual Maintenance Annual replac...

Страница 8: ...connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve devices can be updated by the app When t...

Страница 9: ...neration Time Example Midnight just type 12 then press OK Advanced Settings NOTE Consult your dealer before making any changes We do not recommend changing Advanced Settings unless you have a good und...

Страница 10: ...void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limit...

Страница 11: ...at the set Backwash Time A 0 setting will cancel this feature The Max Value for this item is 29 Example Backwash every 7 days A 07 Factory Setting Cancel setting A 00 To Adjust this Value Press the Se...

Страница 12: ...is turned off to conserve battery power during this time To confirm that the battery is working press either button and the display will turn on for five 5 seconds If power failure occurs while syste...

Страница 13: ...3 To Fast Cycle through regeneration First complete above 2 steps Press and hold the Set Change button for 3 seconds to advance to the next cycle step NOTE Fast Cycle is not necessary unless desired...

Страница 14: ...2 Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply CS TRANS 1 7 Back Plate 20001X005 1 8 Lower Front Base for Cover 20111X002 1 9 Motor...

Страница 15: ...13 AIO Plus Connected Series Valve Body Assembly VALVE PARTS LIST ON FOLLOWING PAGE 29 28 27 26 26 25 22 23 24 22 22 21B 21A 20 19 18 17 17 16 15 14 13 12 11 10 9 8 6 5 4 3 2 1...

Страница 16: ...001 2 18 Injector Screen 20001X222 1 19 Tank O Ring 20561X205 1 20 Distributor Tube O Ring 20561X204 1 21a Flow Meter CS METER 1 21b Flow Meter Plug 20017X201 1 22 3 8 Push Lock 90 Elbow GA Q0620626BV...

Страница 17: ...onnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer at piston drive yoke Remove powerhead mounting screws The entir...

Страница 18: ...or too slow or high service flow Check for media fouling Lack of aeration in water Program valve to draw air more frequently Increase number of minutes in air draw cycle Clean injection assembly and s...

Страница 19: ...ear the error code Manually cycle the powerhead through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve body If the error 3...

Страница 20: ...ers installed for residential use Water conditioners installed for commercial or industrial applications are guaranteed for one 1 year from the date of installation 2 Installation must be made in acco...

Отзывы: