1. Legal Notice and Disclaimers

The entirety of the information contained within this document is

the exclusive property of Nelinor, and it is strictly prohibited for any

part of this document to be reproduced for commercial purposes.

Internal usage, however, is permitted.

Nelinor explicitly disclaims any representations or warranties,

whether express or implied, concerning this document or any of

the equipment and/or software it delineates. This disclaimer

encompasses, without limitation, any implied warranties of utility,

merchantability, or fitness for any specific purpose. Under no

circumstances shall Nelinor or its authorized distributors or dealers

be held accountable for indirect, incidental, or consequential

damages.

The exclusion of implied warranties may not be universally

applicable under certain statutory provisions, and thus the

aforementioned exclusion may not hold true in all cases.

This document does not serve as a substitute for, nor is it intended

to supersede, any local, state, provincial, federal, or national laws,

regulations, or codes pertinent to the installation, electrical safety,

and utilization of battery systems. Nelinor assumes no liability for

adherence or non-adherence to such laws or codes in relation to

battery system installation.

Please be advised that specifications may be subject to alteration

without prior notice. While every effort has been exerted to ensure

the completeness, accuracy, and currency of this document,

Nelinor reserves the right to introduce improvements under specific

circumstances without advance notification. It is imperative to

acknowledge the recognition of all trademarks associated with this

document.

2. Overview

Prior to undertaking any actions concerning the battery system, it

is imperative that you thoroughly review this document, which

encompasses technical information, safety information, installation

guidelines,handling and transportation guidlines, information about

storage location and environmental recommendations,

troubleshooting, and disposal protocols.

Your complete understanding of this document is crucial for

safe and effective operation of the battery system.

The battery system comprises a Li-ion battery storage system with

an integrated control module. The battery can be connected to the

Internet through WiFi for maintenance and firmware updates.

Importantly, it must only be used as stationary equipment and is

designed for indoor use under the conditions outlined in the section

Storage location and environment”

.

Any modifications or changes to the battery system, including

alterations or adjustments, must not be carried out without

obtaining prior written consent from Nelinor. Unauthorized

modifications will result in the nullification of guarantees and

warranty claims. Nelinor shall bear no responsibility for any

damages resulting from such unauthorized alterations.

3. Safety

The Grid Battery system is designed to provide reliable power

storage and management using lithium iron phosphate (LiFePO4)

batteries. While the battery cells themselves are not accessible to

users, it is essential to follow safety precautions to ensure safe

operation and prevent potential hazards. Please adhere to the

following safety guidelines.

NOTE!

Always turn off the unit before unplugging it and never touch

the terminals (metal tips of the plug) right after unplugging it.

Always wait a minimum of 10 seconds before touching the

terminals.

Normal Operation:

Follow Manufacturer Instructions: Always operate the

Grid Battery system according to the manufacturer's

instructions and guidelines.

Routine Maintenance: Schedule regular maintenance

and inspections as recommended by the manufacturer

or qualified technicians.

Inspect for Damage: Before use, carefully inspect the

battery modules for any signs of defects, cracks,

breakage, or damage. If any issues are detected or if

the modules fail to operate correctly, do not use them.

Avoid Cleaning Solvents: Refrain from using cleaning

solvents on the battery modules, as these may damage

their components.

General Safety Practices:

Keep Children and Unauthorized Personnel Away:

Restrict access to the Grid Battery system to

authorized personnel only. Keep it out of reach of

children and pets.

Do Not Modify: Do not modify, alter, or attempt to

enhance the Grid Battery system's performance

without manufacturer authorization.

Proper Disposal: Follow local regulations and the

manufacturer's recommendations for the proper

disposal of the Grid Battery system at the end of its life

cycle.

Emergency Response: Ensure that you have access to

emergency contact information and procedures in case

of accidents or unexpected events involving the Grid

Battery system.

No User Access: Do not attempt to open or access the

battery cells within the Grid Battery system. These

components are not intended for user interaction.

Avoid Physical Damage: Avoid physical damage to the

Grid Battery system by preventing heavy objects from

falling or being placed on top of it.

Temperature Control: Ensure that the Grid Battery

system is installed in an environment with adequate

temperature control to prevent overheating or freezing.

Содержание GRID BATTERY

Страница 1: ......

Страница 2: ...Information 6 7 Handling and transportation 6 8 Storage location and environment 6 9 Operation 7 10 Basic Battery System Operation 7 11 Signals 7 12 Connecting to WiFi and Changing WiFi Connection 7...

Страница 3: ...ction Storage location and environment Any modifications or changes to the battery system including alterations or adjustments must not be carried out without obtaining prior written consent from Neli...

Страница 4: ...producing smoke follow the instructions in the Emergency situations section Return the damaged battery or device to the product s retailer or inquire with the retailer about where the battery can be...

Страница 5: ...5 Installation scheme Countries where electrician is needed e g Finland Sweden Countries where plug n play is accepted e g Germany France...

Страница 6: ...d objects into any part of the battery modules Doing so can compromise the integrity of the modules Avoid Fire Under no circumstances should you throw the battery modules into a fire as this can lead...

Страница 7: ...tween them If you want to reset the WiFi connection or change the connection press and hold the power button for 5 seconds until the lights start flashing indicating that the battery has been disconne...

Страница 8: ...time comes to dispose of your Grid Battery it is crucial to do so responsibly and in compliance with local regulations to protect the environment and ensure safety Follow these guidelines for proper d...

Отзывы: