6. Technical Information

BATTERY PACK INFORMATION

Capacity: 7.2 kWh

Accessible Capacity: 7 kWh

Nominal Voltage of a Single Cell: 3.2 V

Battery Cell Class: A

Battery Chemistry: LiFePo4

Battery Cells: 8

Capacity of a Single Cell: 280 Ah

Number of Battery Cell Cycles (at 80% remaining capacity): 6000

cycles

POWER MODULE INFORMATION

Model: P2

AC Output Voltage: 230 V

AC Output Power (Discharging): 1.8 kW

AC Input Voltage: 230 V

AC Input Power (Charging): 1.8 kW - 2.1 kW

AC Frequency Range: 47-63 Hz

DC Input Range: 23 VDC - 28 VDC

AC to DC Conversion Efficiency: 93%

AC Synchronization Time: 2 Seconds

Overload: 105-115%

BMS FEATURES

Access via local Wi-Fi network

Remote access via the internet

Battery cell balancing

Temperature monitoring

Android and iOS app

Real-time reporting

Individual cell reporting

LED charging indicator

Remote ON/OFF control

ON/OFF button

ENVIRONMENTAL & MECHANICAL DETAILS

Operating Temperature: 0°C-50°C

Storage Temperature: -20°C - 60°C

Installation Environment: Indoor IP20

Dimensions (H/W/D): 25cm60cm24cm

Noise Level: 40-55 dBA

Weight: 59 kg

Certifications: CE, TUV, BC EN/EN62368-1

Network Standards: 50549-1

Values are based on an environmental temperature of 24°C and a

load of 75%

7. Handling and transportation

Protection from Damage: The battery modules and

their components must be shielded from any potential

damage during transportation and handling. Handle

them with care to prevent any harm or degradation of

the system.

Weight Consideration: Be cautious of the system's

weight, which may pose an injury risk. Always handle

the system with care, ensuring safe lifting and

transportation practices.

Avoid impacts: Do not pull, push, bump, drop or step

on the battery modules, as this can cause physical

damage.

No Unrelated Objects: Never insert unrelated objects

into any part of the battery modules. Doing so can

compromise the integrity of the modules.

Avoid Fire: Under no circumstances should you throw

the battery modules into a fire, as this can lead to

hazardous situations.

Avoid Water Exposure: Do not immerse the battery

modules in water or seawater. Water contact can cause

damage and affect the functionality of the modules.

Protect from Oxidizers: Keep the battery modules away

from strong oxidizers, as exposure to these substances

can be harmful.

No Short Circuits: Never short circuit the battery

modules, as this can result in dangerous electrical

discharge.

8. Storage location and environment

IP Classification: The Grid Battery is designed for

indoor storage in an environment that aligns with the

IP20 classification. This classification indicates

protection against foreign objects with a diameter of 12

mm or larger. However, it does not provide protection

against water. The battery system is suitable for

installation in dry indoor environments.

Rubber Feet: The Grid Battery is equipped with four

5mm rubber feet. Ensure that the battery is placed on a

stable and level surface.

Ventilation: Maintain at least a 20 cm clearance in front

of the ventilation holes for the inverter on the left side

and the back side of the batter. This clearance is

necessary to allow for adequate ventilation, which in

turn ensures efficient cooling of the battery

components during both operation and storage.

Avoid Sunlight: Do not store the battery modules

directly under the sun, as extreme heat and exposure

to sunlight can adversely affect their performance and

safety.

Humidity Consideration: The battery modules should

not be stored in a high-humidity environment, as

moisture can lead to corrosion and other issues.

Temperature Range: Store the battery modules in an

environment with a temperature range between -20°C

to +60°C. Extreme temperatures can negatively impact

the modules' performance and lifespan.

.

Содержание GRID BATTERY

Страница 1: ......

Страница 2: ...Information 6 7 Handling and transportation 6 8 Storage location and environment 6 9 Operation 7 10 Basic Battery System Operation 7 11 Signals 7 12 Connecting to WiFi and Changing WiFi Connection 7...

Страница 3: ...ction Storage location and environment Any modifications or changes to the battery system including alterations or adjustments must not be carried out without obtaining prior written consent from Neli...

Страница 4: ...producing smoke follow the instructions in the Emergency situations section Return the damaged battery or device to the product s retailer or inquire with the retailer about where the battery can be...

Страница 5: ...5 Installation scheme Countries where electrician is needed e g Finland Sweden Countries where plug n play is accepted e g Germany France...

Страница 6: ...d objects into any part of the battery modules Doing so can compromise the integrity of the modules Avoid Fire Under no circumstances should you throw the battery modules into a fire as this can lead...

Страница 7: ...tween them If you want to reset the WiFi connection or change the connection press and hold the power button for 5 seconds until the lights start flashing indicating that the battery has been disconne...

Страница 8: ...time comes to dispose of your Grid Battery it is crucial to do so responsibly and in compliance with local regulations to protect the environment and ensure safety Follow these guidelines for proper d...

Отзывы: