7
This module is equipped with a reliable and efficient power supply with low
consumption (standby ≤0.3W) distinguished for its wide range of voltages. It is also
protected against overvoltage on the mains input.
Device compliant with the European standards I-ETS 300 220 and ETS 300 683.
ID
PLATE AND MARKING DATA
RR2-M
receivers have
marking and are destined for use in the European Union without
further requirements.
The
marking on the product, packaging and indications for use provided with the
product indicate ‘presumed conformity to the directives’ issued by the European
Community.
The manufacturer holds the technical archive with documentation providing that products
have been examined and evaluated for conformity to directives.
ID plate data are indicated on a polyethylene adhesive label applied on the product, printed
in black on a grey background; see example aside.
S
CHEMATIC CONNECTION DIRECTIONS
T
HESE INSTRUCTIONS ARE INTENDED FOR TECHNICAL AND SPECIALIZED PERSONNEL
.
T
HUS BASIC SAFETY AND WORKING TECHNIQUES ARE NOT DISCUSSED
.
Diagram 1
Directions for controlling 2 independent loads, such as 2 lamps
1 2 3
Phase
230Vac
Neutral
Button
Led DL1
Local
inputs:
- 2 switches
or
- 2 buttons
2 resistive loads
230V~AC
1250 VA Max
each
Diagram 2
Directions for controlling a single
Ensure that all connections are correct before powering the module; an incorrect
connection may damage the equipment and create a safety hazard.
Phase
230Vac
Neutral
Local
control
inputs:
- 2
buttons
Button
Led DL1
8
Directions for controlling a single-phase asynchronous motor.
Ensure that all connections are correct before powering the module; an incorrect
connection may damage the equipment and create a safety hazard.
1 2 3
Single-phase
asynchronous
motor 230Vac
Max 1250 VA @
cosφ =1
Max 500 VA @
cosφ = 0.4
M
Ensure that all connections are correct before powering the module; an incorrect
connection may damage the equipment and create a safety hazard.
phase
asynchronous
motor 230Vac
Max 1250 VA @
=1
Max 500 VA @
cosφ = 0.4