background image

en

    Important safety information

4

:

Warning

Risk of burns!

The accessible parts become very hot when in 

operation. Never touch hot parts. Keep 

children at a safe distance.

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

Items placed on the appliance may fall 

down. Do not place any objects on the 

appliance.

Risk of injury!

The light emitted by LED lights is very 

dazzling, and can damage the eyes (risk 

group 1). Do not look directly into the 

switched on LED lights for longer than 100 

seconds.

:

Warning

Risk of injury!

Risk of trapping body parts when opening and 

closing the glass front. Do not reach into the 

area behind the glass panel, and keep your 

fingers away from the hinges.

:

Warning

Hazard due to magnetism!

Permanent magnets are inserted in the 

appliance front. They may affect electronic 

implants, e.g. heart pacemakers or insulin 

pumps. Wearers of electronic implants must 

stay at least 10 cm away from the appliance 

front.

:

Warning

Risk of electric shock!

A defective appliance may cause electric 

shock. Never switch on a defective 

appliance. Unplug the appliance from the 

mains or switch off the circuit breaker in the 

fuse box. Contact the after-sales service.

Risk of electric shock!

Incorrect repairs are dangerous. Repairs 

may only be carried out and damaged 

power cables replaced by one of our 

trained after-sales technicians. If the 

appliance is defective, unplug the appliance 

from the mains or switch off the circuit 

breaker in the fuse box. Contact the after-

sales service.

Risk of electric shock!

Do not use any high-pressure cleaners or 

steam cleaners, which can result in an 

electric shock.

Causes of damage
Caution!

Risk of damage due to corrosion. Always 

switch on the appliance while cooking to avoid 

condensation. Condensate can produce 

corrosion damage.
Always replace faulty bulbs to prevent the 

remaining bulbs from overloading.
Risk of damage due to ingress of humidity into 

the electronic circuitry. Never clean operator 

controls with a wet cloth.
Surface damage due to incorrect cleaning. 

Clean stainless steel surfaces in the direction 

of the grain only. Do not use any stainless 

steel cleaners for operator controls.
Surface damage due to strong or abrasive 

cleaning agents. Never use strong and 

abrasive cleaning agents.
Risk of damage from returning condensate. 

Install the exhaust duct in such a way that it 

falls away from the appliance slightly (1° 

slope).
Risk of damage as a result of incorrect 

loading of design elements. Do not pull design 

elements.Do not place objects on the design 

elements or hang objects from them.

Содержание N 90 D95IPU1N0B

Страница 1: ...Dunstabzugshaube de...

Страница 2: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 3: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 4: ...the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the a...

Страница 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain he...

Страница 6: ...nction The noise reduction function reduces the fan noise Switching on Note This function can be used at any fan setting except fan setting The function will remain active even after the fan is switch...

Страница 7: ...filter and If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 16 The saturation indicators can be re...

Страница 8: ...ymbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touc...

Страница 9: ...g over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hol...

Страница 10: ...ol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset...

Страница 11: ...he Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that cannot be regenerated Take your finger off the Q symbol This will switch the electronic controller over...

Страница 12: ...symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on To...

Страница 13: ...ing over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched on Touch and ho...

Страница 14: ...bol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch...

Страница 15: ...d charcoal filter Metal grease filter and activated charcoal filter and If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning an...

Страница 16: ...ote Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold...

Страница 17: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher...

Страница 18: ...iance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an...

Страница 19: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Страница 20: ...rated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For...

Страница 21: ...n location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installat...

Страница 22: ...l vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cann...

Страница 23: ...KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs m...

Страница 24: ...ood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood...

Страница 25: ...out a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP...

Страница 26: ...st air pipe dia 120 mm 1 Fit the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Use suitable means to seal both joints Attaching the fl...

Страница 27: ...sing two screws 7 Clip the lower flue duct section in at the retaining bracket The connection cable must not be damaged Note If an air recirculation optional accessory has been fitted and the extracto...

Страница 28: ...Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001159981 9001159981 970606 de...