background image

 Installation  

en

27

6.

Screw the flue duct section to the sides of the 

retaining bracket using two screws. 

©

7.

Clip the lower flue duct section in at the retaining 

bracket. The connection cable must not be 

damaged. 

ª

Note: 

If an air-recirculation optional accessory has been 

fitted and the extractor hood is to be operated without a 

flue duct, the cable must be wound onto the connector.

Содержание N 90 D95IPU1N0B

Страница 1: ...Dunstabzugshaube de...

Страница 2: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 3: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 4: ...the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the a...

Страница 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain he...

Страница 6: ...nction The noise reduction function reduces the fan noise Switching on Note This function can be used at any fan setting except fan setting The function will remain active even after the fan is switch...

Страница 7: ...filter and If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 16 The saturation indicators can be re...

Страница 8: ...ymbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touc...

Страница 9: ...g over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hol...

Страница 10: ...ol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset...

Страница 11: ...he Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that cannot be regenerated Take your finger off the Q symbol This will switch the electronic controller over...

Страница 12: ...symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on To...

Страница 13: ...ing over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched on Touch and ho...

Страница 14: ...bol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch...

Страница 15: ...d charcoal filter Metal grease filter and activated charcoal filter and If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning an...

Страница 16: ...ote Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold...

Страница 17: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher...

Страница 18: ...iance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an...

Страница 19: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Страница 20: ...rated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For...

Страница 21: ...n location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installat...

Страница 22: ...l vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cann...

Страница 23: ...KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs m...

Страница 24: ...ood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood...

Страница 25: ...out a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP...

Страница 26: ...st air pipe dia 120 mm 1 Fit the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Use suitable means to seal both joints Attaching the fl...

Страница 27: ...sing two screws 7 Clip the lower flue duct section in at the retaining bracket The connection cable must not be damaged Note If an air recirculation optional accessory has been fitted and the extracto...

Страница 28: ...Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001159981 9001159981 970606 de...

Отзывы: