Doc no#: 306-0008-002-001 Rev500 Neets 4 relay
Page 14
Linking two relays together
As mentioned earlier, it is possible to link two relays together. Two linked relays are not able to be “Set” at
the same time and further more it is possible to define the time from one relay is released to the next can
be “Set”.
Command:
Group=<G>,Action=<X>[,Delay=<W>][,Unit=<Z>]\CR
Below you find some examples on how to link and unlink relays together:
1. Link relay 1 and 2 together on all relay boxes connected.
Group=1,Action=Lock\CR
2. Link relay 3 and 4 together and set the safety delay to 3,6 seconds on all units connected.
Group=2,Action=Lock,Delay=3.6\CR
3. Unlink relay 1 and 2 on the relay box with ID number 3.
Group=1,Action=Unlock,Unit=3\CR
Group=<G>
Description
1
Relay 1 and 2
2
Relay 3 and 4
Action=<X>
Description
Lock
Lock the selected group.
Unlock
Unlock the selected group. The relay in the group is no longer linked.
Delay=<W>
Description
0-25.5
Set the time (in seconds) from one relay is released to the next in the group can
be “Set”. The minimum step is 100 ms.
Unit=<W>
Description
0-4
Set the ID number of the relay box this command is intended to. If Unit number is
0 or not used the message will be send to all relay boxes.
Содержание 4 Relay box
Страница 1: ......