Exhaust Rail System 920/1500
11
EN
3
Description
3.1
Technical data
Table 3-1: Technical data
Exhaust Rail System 920/1500
Mounting height, vehicles in motion
3–5 m (10–13 ft)
Mounting height, stationary trucks
4–5 m (11.5–13 ft)
Hose diameter, vehicles in motion
100 mm (4") or 150 mm (6")
Hose diameter, stationary trucks
150 mm (6")
Hose length
5 m (16 ft) or 6 m (20 ft)
Total rail length
2.5-100 m (8–328 ft)
Weight, trolley
11 kg (24.2 lb)
Weight, hose NR-CP (Ø100)
0.86 kg/m (0.58 lb/ft)
Weight, hose NR-CP (Ø150)
1.25 kg/m (0.84 lb/ft)
Weight, rail incl. rubber strips
6.7 kg/m (4.5 lb/ft)
Recommended airflow for each trolley,
cars, hose Ø100
400 m
3
/h (235 cfm)
Recommended airflow for each trolley,
trucks, slang Ø150
1000 m
3
/h (590 cfm)
Temp. resistance
continuosly max. 150 °C (300 °F)
Max. vehicle speed
15 km/h*
Material, rubber lips
EPDM
Material, suction trolley
Glassfibre composite
Material, rail
Aluminium
Material, hose
EPDM
* Systems with automatic disconnection.
4
Installation
4.1
Mounting instruction
Rail sections and fan
See Instruction manual, "Mounting Instructions, Rail".
4.2
Installation checklist
When the mechanical assembly and fan connection of the system is complete,
it is ready for use after doublechecking the following:
•
Check the air flow (400 m
3
/h for cars, 1000 m
3
/h for trucks/buses
are recommended) in the nozzle opening with an air flow indicator.
If needed, check the fan impeller rotation direction and/or damper
function.