NED
UME-0064-01
XCM40170DLMT2CXP
21
5 Camera Control
The camera can be controlled by the frame grabber board through the camera’s
control registers. The camera supports GenICam, and so can be easily controlled
by a GenICam-compatible frame grabber. The camera control software which
came with your frame grabber should be used for camera control.
Once the camera settings have been made and saved, the camera will operate
without further setting.
5.1 Flow of Camera Control
5.1.1 GenICam overview
The camera control register information is saved inside the camera (XML file)
The frame grabber board reads the XML file during Discovery, and acquires the register
information.
Camera control is enabled after Discovery.
5.1.2 Camera Control registers
The camera can be controlled the function through camera register by frame grabber board.
Table 5-1-2-1 List of Camera Control Registers
Control Item
Address
R/W
VAL
Control Description
Category
:
Device Control
Device User ID
0x0000_20C0
~
0x0000_20CF
R/W
(ASCII code)
User define ASCII code
Category
:
CoaXPress
CxpLinkConfig
0x0000_4014
R/W
0x10030/0x20030 Single CXP-2 / Dual CXP-2
Category
:
Image Format Control
Width
0x0000_A000
R
2048 / 4096
Binning Horizontal
=2, 2048 Pixels
Binning Horizontal
=1, 4096 Pixels
Height
0x0000_A004
R
1
1 Line
Binning Horizontal
0x0000_A280
R/W
1 / 2
1=Off / 2=2 Pixels binning
See 5.3.22