NED
SUi7440
UME-0031-03
24
4.1.5 Memory Setup Values (Factory Settings)
The memory setup values (factory settings) are shown below.
Table 4-1-5-1 Memory Setup Values (Factory Settings)
Control Item
CMD
VAL
Control Description
Exposure Mode
t
0
Free Run ( Programmable setting fixed time)
Free run Exposure Mode scan
time
i
4798
4798 CK (191.92
µ
s) scan period time
Odd Gain (1 ~ 7400 pixel)
g
162
2.3982 times
Odd Gain (1 ~ 3700 pixel)
gf
162
2.3982 times
Odd Gain (3701 ~ 7400 pixel)
gb
162
2.3982 times
Even Gain (1 ~ 7400 pixel)
G
162
2.3982 times
Even Gain (1 ~ 3700 pixel)
GF
162
2.3982 times
Even Gain (3701 ~ 7400 pixel)
GB
162
2.3982 times
Odd Offset (1 ~ 7400 pixel)
o
1
1DN
Odd Offset (1 ~ 3700 pixel)
of
1
1DN
Odd Offset (3701 ~ 7400 pixel)
ob
1
1DN
Even Offset (1 ~ 7400 pixel)
O
1
1DN
Even Offset (1 ~ 3700 pixel)
OF
1
1DN
Even Offset (3701 ~ 7400 pixel)
OB
1
1DN
Video Output Switching
v
0
8 bit 1 Tap
Pixel Correction selection
C
0
Activate Factory White Pixel Correction
Data
Pixel Correction target level
M
2048
Set Pixel Correction Target Data Level to
128DN
Select Data Level Adjustment
c
0
Data Level Adjustment Deactivated
Data Level Adjustment Minimum
Value
s
0
Set Data Level Adjustment Minimum
Value to 0DN
Data Level Adjustment
Maximum Value
S
4095
Set Data Level Adjustment Maximum
Value to 4095DN
Test Pattern
T
0
Off