NED
NUCLi7370AT6
UME-0069-03
44
4.8.4
Pseudo-exposure control mode (Level)
In Pseudo-exposure control mode
(Level)
, the exposure time is determined by the
High time of the trigger pulse. Each exposure starts with the rising edge and the line
period is determined by the time from rising edge to rising edge of trigger pulse. The
range of programmable exposure time, the timing chart of the exposure and the
readout are shown below.
Table 4-8-4-1 Pseudo-exposure control mode (Level)
h
Trigger pulse High time
≧
57
l
Trigger pulse Low time
≧
57
r
Readout time (LVAL)
52.2 (at 6-tap output)
85.9 (at 3-tap 85MHz output)
104.3 (at 3-tap 70MHz output)
(unit : μs)
Trigger
(CC1)
Exposure
Readout
(LVAL)
h
l
r
Figure 4-8-4-1 Pseudo-exposure control mode