4.8
Exposure Mode and Timing Chart
The camera has four exposure modes. The overview of each mode and the timing
are as follows.
4.8.1 Free Run Exposure Mode
In free-run exposure mode, the camera generates its own internal control signal
based on two programmable parameters, exposure time and readout time. The range
of programmable exposure time and the timing chart of the exposure and the readout
are shown below.
Table 4-8-1-1 Free Run Exposure Time
e
Programmable exposure time
57 ~ 32767 (at 6-tap output)
88 ~ 32767 (at 3-tap 85MHz output)
114 ~ 32767 (at 3-tap 70MHz output)
r
Readout time
(LVAL)
52.2 (at 6-tap output)
85.9 (at 3-tap 85MHz output)
104.3 (at 3-tap 70MHz output)
(unit : μs)
Exposure
Readout
(LVAL)
e
r
Figure 4-8-1-1 Free Run Exposure Mode