18
0301 162-00
SETTING THE BASIC UNIT
AND THE DECIMAL POINT
When the "Basic unit / DP" (basic coin value) function of the
"programming" menu is displayed, the value of the basic
coin as well as the position of the decimal point can be
modified.
Press the confirm button “ ” from the "programming" menu
to display the current value of the basic unit.
Use the “ ” and “ ” buttons to alternate between the value
of the basic coin and the number of the decimal point
position "DP", i.e.:
0
disabled decimal point
1
XXX.X
2
XX.XX
3
X.XXX
When pressing the change button “ ”, these values start
blinking and can be modified as necessary.
INITIALISING
When the "Initialising" function is displayed, the machine
can be initialised, thus resetting all default data.
This function is used in case of stored data error or
replacement of the EPROM.
All statistical data is reset.
Press the confirm button “ ” and the message "Confirm?"
is displayed. Press the button “ ” again and the message
"Working" is displayed for a few seconds.
Also the machine configuration is by default and
will have to be reconfigured. The default configu-
ration is for an automatic machine with water
supply from the mains.
SETTING THE MACHINE CODE
When the "Machine code" function is displayed the identi-
fication code number of the machine can be changed (from
the default 0000 to a number up to 9999).
IMPORTANT NOTICE!!!
When the machine is initialised, the configuration will
reset to the default values: "Water supply from the
mains/automatic cup dispensing".
Therefore, after initialising the machine must be
reconfigured.
FAST CYCLES
When this function is enabled, some of the time that is
useful for improving the drink quality is eliminated.
Instant selections
- All of the products that compose the drink are dispensed.
- The "post-whipping" time is eliminated.
Espresso selections
- Pre-brewing of ground coffee is not performed.
- The pump, used to increase the boiler pressure after an
instant drink selection, is not started.
- The "post-whipping" time is eliminated.
SELECTION COUNTER
This function is used to lock the machine after a preset
number of coffee selections, and a preset number of
instant selections.
Since this is a control tool used only by the vending
operator, a 4-digit password must be entered.
After entering the password, the number of selections after
which the machine locks can be set, the number of selec-
tions already made can be read and the lock counter can
be reset.
NB: The counters are set to zero by default;
With the counters set to zero, this function is disabled.
Press the confirm button “ ” to display the current
code; when pressing the change button “ ” the first
digit will start blinking.
The buttons will have numeric values.
When pressing a button, the blinking digit will take
on the displayed value and the next digit starts
blinking.
MACHINE CONFIGURATION
When the "Machine Config." function is displayed,
the machine configuration can be changed, and
namely:
- water supply from the mains / internal tank
- fast/better dispensing cycles.
Press the confirm button “ ” to display the current
status; when pressing the change button “ ” the
status starts blinking and can be changed with the
“ ” and “ ” buttons.
Содержание Brio 250
Страница 2: ......
Страница 4: ......
Страница 38: ...NECTA VENDING SOLUTIONS SpA Sx30504...
Страница 39: ...Brio Caff 120V UL...
Страница 40: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 41: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 42: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 44: ......