© by NECTA VENDING SOLUTIONS SpA
16
0301 162-00
PROGRAMMING
When pressing the programming button located on the
push-button card internal side twice (see Fig. 20), the
machine goes into "Programming" mode; a password is
requested, corresponding to the keys sequence "8", "6",
"5" and "7".
After inserting the password the display shows the mes-
sage "Programming" for approx. 2 seconds, and after this
the first option of the programming menu appears on the
display enabling the following functions:
"Present failures"
reading present failures
"Water dose"
water dose setting
"Powd. dose"
powder dose setting
"Set Prices"
price setting
"Set Prices/Select"
price/selection combination
enable/disable selections
"Basic unit / DP"
basic coin value setting
and decimal point position
"Initialising"
RAM initialising
"Machine code"
setting the machine
identification code
"Machine Config."
setting the machine version
(fast/better cycles - mains/tank)
"Selec. counter"
setting the number of selections
after which the machine will lock
"MDB data"
MDB protocol management
"Consecutive sel."
setting the number of selections
after which the machine will
pause for heating
"Pre-grinding"
setting grinding during the
selection to be used for the
next selection
"Set date/time"
setting the clock
"Set washing"
setting the time for automatic
washing
"Set band"
setting the time of bands with
sales at a different price
"Set price band"
setting the sales price of bands
with sales at a different price
"Set jug"
number of consecutive
selections with jug facilities key
"Set language"
language of displayed messages
"Set waste counter"
number of brewing cycles
(plus version only)
The following operations are also possible:
- failure reset
- machine installation
- statistics display
- statistics printout
- statistics reset
At this point the buttons are assigned different functions as
indicated in the figure below.
increase data unit (+1)
decrease data unit (-1)
exit function
confirm function
previous function
next function
confirm data
change data
reset failures
installation
reset statistics
print statistics
display statistics
delete data
The buttons shown within the dotted line perform direct
functions, the ones outside are used to scroll through the
menu or to change data.
IMPORTANT NOTICE!!!
When initialising the machine, the configuration is
given the default values "Supply from the mains/
automatic cup dispensing".
THEREFORE AFTER INITIALISING, THE MACHINE
SHOULD BE RECONFIGURED.
DISPLAYING THE PRESENT FAILURES
When the "Present failure" function from the "program-
ming" menu is displayed, pressing the confirm button “ ”
will display the error code of the current failure;
when pressing button “ ” the error code of the next
applicable failure is displayed.
If no failure is currently present, pressing confirm button
“ ” will display the message "No Failure".
The 14 possible failures are shown in the following cases:
AIR-BREAK FAILURE
The machine will lock if the lack of water condition is not
signalled by the microswitch after 7 selections.
Содержание Brio 250
Страница 2: ......
Страница 4: ......
Страница 38: ...NECTA VENDING SOLUTIONS SpA Sx30504...
Страница 39: ...Brio Caff 120V UL...
Страница 40: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 41: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 42: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 44: ......