– 241 –
CHAPTER 3
System Messages
3-I:
Digital Line Failure
This message displays after [3-H] Digital Line Warning lasts in the DTI card over the particular time. This
failure may cause a speech path fault to the DTI card.
Location of faulty PM
Kind of fault
Location of faulty circuit card (This
data is valid when
is 0FH)
Default Alarm
Default Grade
Grade Modified
Lamp Modified
SUP
3
1:
XXXX
0000
XXXX
XXXX
2:
XXXX
XXXX
XXXX
XXXX
3:
XXXX
XXXX
XXXX
XXXX
4:
XXXX
XXXX
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b6
b5
b4
b3
b2
b1
b0
b7
b6
b5
b4
b3
b2
b1
b0
b7
b6
b5
b4
b3
b0
1 2
3 4
3 4
3 4
3 4
3 4
3 4
3 4
3 4
3 4
3 4
3 4
b0-b4: Group
b5, b6: Unit
b7:
0/1 = Even-numbered MG/Odd-numbered MG
1
01H = Frame alignment loss occurs 100 times a day
03H = Slip occurs 50 times a day
04H = Multi-frame alignment loss occurs 110 times a day
06H = Frame alignment loss lasts for two to three seconds
07H = Bit error rate is over 10
-4
09H = Warning signal (AIS) from the opposite office has been received for
one second continuously.
0BH = Multi-frame alignment loss lasts for two to three seconds
0FH = Digital Line is not restored
2
b3-b7: Group number
3
2
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......