Chapter 1 MAINTENANCE SERVICES
1-35
NWA-033627-001 Rev.4.0
95ch1001.fm
VoIP LOG COLLECTION
NOTE:
To use Hyper Terminal, select
File
Properties
, and set emulation to VT100.
• To collect the fault logs and call logs, be sure to set the CPU blade to on-line mode (set SENSE
switch to 0-4).
(2) Conditions of fault log collection
• By collecting fault logs, you can specify the reset causes and reset time.
• By collecting fault logs, you can calculate the number of sending control packets, the number of
re-sending control packets, the number of failed re-sending control packets, the number of
received control packets, the received error control packets, and the error number of control
sequences.
• The fault logs are collected by the following timing.
- When IP Stations login to the system, and when the VoIPDB is in online status
- When you set the system data for fault logs collection (CMEA Y=6>11) from PCPro/CAT
• The output format of fault logs is as follows.
STN31100 08/04/30 12:48:19
DATA=1:RESET CAUSE
1=06440755 08/04/25 17:38:35
2=06440755 08/04/25 18:23:19
3=06440755 08/04/25 18:26:06
4=06440755 08/04/28 10:34:17
5=06440755 08/04/28 14:50:03
6=06440755 08/04/28 16:23:48
7=06440755 08/04/28 20:26:53
8=06440755 08/04/30 12:48:03
DATA=2:CONTROL PACKET COUNTER (PROTOCOL=2)
1=000016AD 2=000016AD 3=00000008 4=00000001
5=000016A6 6=00000C0A 7=00000000
DATA=3:REGISTRATION NG
1=FF-DRS0 2=FF-DRS0 3=FF-DRS0 4=FF-DRS1
5=FF-DRS1 6=FF-DRS1 7=FF-DRS2 8=FF-DRS2
TIME OUT
1
2
3
3
4
3
7
3
8
9
5
6
4
5