Chapter 2 TROUBLESHOOTING
2-43
NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Dial Tone is not returned from dis-
tant office.
In case of COT blade
(1)
(2)
Disconnect the trunk from the line on the
MDF.
Connect a test telephone set to the C.O. line
(distant office side) on the MDF.
(3)
(4)
If Dial Tone is returned by going off-hook
on the test telephone set, check for trouble
with wiring on the MDF and the trunk
blade.
If not, there is a problem with the distant
office or the C.O. line.
(1) Trunk blade.
In case of ODT blade
(1)
(2)
Disconnect the trunk from the line on the
MDF.
To perform a Loopback Test, make a back
to back connection of the trunk blade and
another trunk within the system at the
MDF.
NOTE:
This test only works when the
trunks are assigned for type V
operation.
A
CHECK
SW
MDF
TRUNK
To Distant Office
Test Telephone Set
REPLACE
CHECK
B