Chapter 2 TROUBLESHOOTING
2-32
NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Line Status and Remedial Action for Hardware Test
• IP STATION
Line Status and Remedial Action for Software Test
• SINGLE LINE TELEPHONE/MULTILINE TERMINAL
INDICATED
DATA
LINE STATUS
REMEDIAL ACTION
06
DLC blade down
Replace the blade with a known good one and check to
see if the same failure occurs.
08
Line failure detect
Replace the terminal with a known good one and check
to see if the same failure occurs.
INDICATED
DATA
LINE STATUS
REMEDIAL ACTION
00
Terminal is not connected
Check the LAN cable connection between the ter-
minal and the PBX.
Check the condition of LAN cable connection by
transmitting the ping packet.
Confirm the condition of the LAN device (such as
power of the HUB) connected to the VoIPDB.
01
Terminal is connected
No action is required.
INDICATED
DATA
LINE STATUS
REMEDIAL ACTION
01
Idle
No action is required.
02
Line Lockout
Place the handset of the station in line lockout back
onto the hookswitch.
Other than
01, 02
Busy
No action is required.
1
2
3