Chapter 2 Message List
390
iSM13603: Partition that specified drive
character assigned has multiple
partitions/extents.
[Classification] ERROR
[Explanation]
Specified disk to which the drive letter is allocated is configured in multiple
partitions, or volume in the disk is configured in multiple extensions (physical
disk).
This message is output on Windows system.
[Measures]
Physical disk status can be confirmed by Disk Management (Computer
Management) for Windows. Settings for the replication operation option
setting file (iSMrpl.ini) must be changed to execute operation for multiple
partitions. However, operation for multiple extensions is not allowed.
iSM13604: Specified partition does not exist.
[Classification] ERROR
[Explanation]
Specified partition does not exist.
This message is output on Windows system.
[Measures]
Check the partition and re-execute.
iSM13605: Specified drive number does not
exist.
[Classification] ERROR
[Explanation]
Specified disk number does not exist.
This message is output on Windows system.
[Measures]
Check the specified physical drive and re-execute.