Chapter 2 Message List
29
iSM03000
∼
iSM03100: Disk Array is not specified in the
config file. detail=<
aa-bbbb
>
[Classification] WARNING
[Explanation]
It indicates that no monitoring disk array exists for the iSM server because disk
array has not been specified.
aa-bbbb :
Detailed
information
(This
code is not disorder reason but a
value for maintenance.)
[Measures]
Check description of agent section (disk array or auto_find_spf) in the
environment definition file. If no problem is found, check disk connection
environment and restart the iSM server.
On Windows system, check environment settings (disk array information). If
no problem is found, check disk connection environment and restart the iSM
server.
iSM03101: Object Disk Array does not exist.
detail=<
aa-bbbb
>
[Classification] WARNING
[Explanation]
It shows that the iSM server is started with no disk arrays to be controlled,
because no disk arrays to be controlled are found.
aa-bbbb
: Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures]
Check description of agent section (diskarray or auto_find_spf) in the
environment definition file. If no problem is found, check disk connection
environment and restart the iSM server.
On Windows system, check environment settings (disk array information). If
no problem is found, check disk connection environment and restart the iSM
server.