42
15. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
04H
DATA00 to DATA03
CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: GREEN Gain Flag
02H
DATA02: GREEN Gain 1 (Bias)
D8H: -40
FFH: -1
00H: 0
IEH: +30
DATA03: GREEN Gain2 (Drive)
D8H: -40
FFH: -1
00H: 0
IEH: +30
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: GREEN Gain Flag
02H
16. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
04H
DATA00 to DATA03
CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BLUE Gain Flag
03H
DATA02: BLUE Gain1(Bias)
D8H:-40
FFH:-1
00H: 0
IEH: +30
DATA03: BLUE Gain2(Drive)
D8H: -40
FFH:-1
00H: 0
IEH:+30
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BLUE Gain Flag
03H
17. NR MODE Set
Function
The external control equipment sets the NR (Noise Reduction) mode of the
plasma monitor.
Transmission Data
DFH
80H
60H
C0H
01H
DATA00 CKS
DATA00: 01H: NR OFF
02H: NR-1
03H: NR-2
04H: NR-3
ACK
7FH
60H
80H
C0H
01H
DATA00 CKS
DATA00: 01H: NR OFF
02H: NR-1
03H: NR-2
04H: NR-3
18. BASS Gain Data
Function
The external control equipment changes the BASS gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BASS Gain Flag
03H
DATA02: BASS Gain
F3H: -13
FFH: -01
00H: 0
01H: +01
0DH: +13
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BASS Gain Flag
03H
19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: TREBLE Gain Flag
04H
DATA02: TREBLE Gain
F3H: -13
FFH: -01
00H: 0
01H: +01
0DH: +13
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: TREBLE Gain Flag
04H