192
7. Maintenance
❺
Replacing the Filters
It is recommended that the filters are cleaned after every 5000 hours of use and replaced after every 10000 hours of
use. These hours can vary depending on your usage environment.
There are two filters, one located at the front of the projector and one on the side.
Optional filters NP03FT (two filter) are available.
Small one for the front
Large one for the left side
NOTE:
• Replace both filters with the new ones at the same time.
• Before replacing the filters, use a vacuum cleaner to vacuum dust and dirt from the vents (inlet) of the projector and use a dry
soft cloth to wipe dust off the cabinet.
• The projector contains high-precision parts. Keep out dust and dirt during filter replacement.
• Do not wash the filter with water. Water will damage the filter membrane.
• Attach the filter in the correct orientation. Failure to do so may cause dust and dirt to enter inside the projector, resulting in projec-
tor malfunction.
Filter cover
Inlet
(The filter is inside)
Filter cover
Inlet
(The filter is inside.)
Replacing the filter on the left side
1. Remove the filter cover.
(1) Loosen each of the two knobs by turning them counter
-
clockwise.
• The knobs are not removable.
• If the knob is too tight to turn, use a Phillips screw
-
driver.
(2) Remove the filter cover by sliding it to the left and pulling
it out.
1
2
Filter cover
Notch
Knob
Содержание PH1000U
Страница 1: ...Projector PH1400U User s Manual Model No NP PH1400U ...