User’s Manual U17307EJ2V0UM
49
CHAPTER 5 USAGE EXAMPLE
This chapter explains a series of basic operations of the FPL2 with the GUI software, taking a case where the
µ
PD78F9222 is used as the target device as an example. This chapter covers how to start the system, execute the
[Autoprocedure (EPV)] command, and program the target device.
Refer to
CHAPTER 4 OPERATION USING GUI SOFTWARE
for the other commands and applications.
O Series of operations described in this chapter
The conditions of the series of operations described in this chapter are as follows:
•
Target system
Target device:
µ
PD78F9222
Voltage level:
3 V
Communication: UART
CH0
•
FPL2
Parameter file:
78F9222.PRM
Clock setting:
8 MHz
Port:
UART-ch0 (115,200 bps)
MODE switch:
3 V
Operation mode:
Chip
Write HEX:
FPL2_TEST.HEX
Option setting:
Blank check before Erase
Checksum
after
Program
(1) Installing the GUI software
Install the FPL2 GUI software in the host machine you are using, by referring to
CHAPTER 3 SOFTWARE
INSTALLATION
(if the software has not been installed yet).
(2) Installing the driver
Install the USB driver in the host machine you are using, by referring to
CHAPTER 3 SOFTWARE
INSTALLATION
(if the driver has not been installed yet).
(3) Installing the parameter file
Copy the parameter file for the
µ
PD78F9222 to the hard disk and install it in <
FPL2-installation-path
>\PRM.
Download the parameter file from the following:
http://www.necel.com/micro/ods/eng/index.html (website in English)