NDA-24299
CHAPTER 7
Page 175
Revision 1.0
TROUBLESHOOTING
23-U FCH Status Information
Figure 7-16 23-U FCCH Status Information
9.1 FLTINF = 00H Initial Setting Failure
illustrates the message that is displayed when the Ethernet Controller Initial Setting ends in failure.
Note 1:
FLTINF (Fault Information) consists of the following:
OOH:
Initial Setting Failure Notification
18H
Spanning Tree Abnormal Answer Notification
1DH
ETHER Transfer Failure Notification
1EH
Spanning Tree Generation End Notification
1FH
Spanning Tree Generation Start Notification
85H
Check Sum Verify Failure Notification
Note 2:
When TRC = 1, the subsequent data indicates “Date Information” + “Primitive Contents”
* The detailed fault information is explained on the following pages.
1. xx0x xxxx xxxx xxxx 2. xxxx xxxx xxxx xxxx.........
MG
U
G
FCH Mounting Location
FCH Mounting Location
MG: Module Group (0/1)
U: Unit (0-3)
G: Group (00-23)
FCH CKT No.
Circuit Number of FCH (0 - 7)
FLTINF: Fault Information
FLTINF
TRC RS
b0
b7
b0
b7
b0
b7
b0
b7
b0
b7
:
:
:
:
DATA*
DATA*
* The contents vary depending on FLTINF.
0
Содержание NEAX 2400 IPX
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24299 ISSUE 1 STOCK 200776 Fusion Network System Manual ...
Страница 15: ...LIST OF TABLES NDA 24299 Page x Revision 1 0 This page is for your notes ...
Страница 73: ...CHAPTER 4 NDA 24299 Page 58 Revision 1 0 This page is for your notes ...
Страница 159: ...CHAPTER 5 NDA 24299 Page 144 Revision 1 0 DATA PROGRAMMING Office Data Sheets This page is for your notes ...