84
6. Appendix
• Timing chart of GPIO control
Example of Select Preset Button
Off at least 500 ms
at least 500 ms
approx. 200 ms
on
off
on
off
8-27
5-24/6-25/7-26
Execute
Select Preset Button
time
Example for turning the image douser (Douser) on
Off at least 500 ms
at least 500 ms
approx. 200 ms
on
off
on
off
5-24/7-26
6-25/8-27
Execute
Image douser (Douser) ON
time