Problem Solving 5-19
BIOS Messages (Continued)
Message
Description
Parity Check 1
nnnn
*
or
Parity Check 2
nnnn
*
A parity error was found in the system bus (Parity Check
1) or the I/O bus (Parity Check 2). BIOS attempts to
locate and display the address on the screen. If it cannot
locate the address, it displays.
Press <F1> to resume, <F2> to Setup
Displayed after any recoverable error message.
Press <F2> to enter SETUP
Optional message displayed during POST. Can be turned
off in Setup.
Previous boot incomplete - Default
configuration used
Previous POST did not successfully complete. POST
loads default values and offers to run Setup. If the
failure was caused by incorrect values and they are not
corrected, the next boot will likely fail. On systems with
control of wait states, improper Setup settings can also
terminate POST and cause this error on the next boot.
Run Setup and verify that the wait-state configuration is
correct. This error is cleared the next time the system is
booted.
Real time clock error*
Real time clock fails BIOS test. May require board repair.
Shadow Ram Failed at offset:
nnnn
*
Shadow RAM failed at offset
nnnn
of the 64K block at
which the error was detected.
nnnn
Shadow RAM Passed
Where
nnnn
is the amount of shadow RAM in kilobytes
successfully tested.
System battery is dead - Replace and run
SETUP
The CMOS clock battery indicator shows the battery is
dead. Replace the battery and run Setup to reconfigure
the system.
System BIOS shadowed
The system BIOS is copied to shadow RAM.
System cache error - Cache disabled*
The RAM cache failed the BIOS test and BIOS has
disabled the cache.
System CMOS checksum bad - run
SETUP
The system CMOS has been corrupted or incorrectly
modified, perhaps by an application program that
changes data stored in CMOS. Run Setup and
reconfigure the system either by getting the default
values or making your own selections.
System RAM failed at offset:
nnnn
*
The system RAM failed at offset
nnnn
of the 64K block at
which the error was detected.
nnnn
System RAM Passed
Where
nnnn
is the amount of system RAM in kilobytes
successfully tested.
Содержание LS2400
Страница 1: ...U s e r s G u i d e SERVER LS2400...
Страница 2: ...xxx...
Страница 3: ...U s e r s G u i d e SERVER LS2400...
Страница 9: ...Contents vii Glossary Equipment Log Index xxxx...
Страница 10: ......
Страница 40: ......
Страница 127: ...A System Cabling Before You Begin Static Precautions Standard Configuration RAID Configuration...
Страница 135: ...B System Setup Utility System Setup Utility SSU Creating SSU Diskettes Running the SSU Exiting the SSU...
Страница 150: ......
Страница 170: ......
Страница 185: ...xx...
Страница 186: ...904475 04...