![NEC Express5800/R120i-2M Скачать руководство пользователя страница 92](http://html2.mh-extra.com/html/nec/express5800-r120i-2m/express5800-r120i-2m_installation-manual_4811566092.webp)
1. List of Windows Event Logs
Installation Guide (Windows Server 2019)
92
Chapter 3 Appendix
ID
Source
Level
Message (Description)
Timing when an event is logged
Action
All Windows OS ”System Log”
4367
Agentless Management
Service
Error
Description of IML Event ID 4367, Class Code 17, Event Code 12:
Redundancy status changed to decreased by adapter in slot x, port
xIf redundancy decreased, check the connection to the adapter and
validate the connectivity from the server to any external device,
including the cabling. If no problems are found, the adapter or other
connectivity device may need replacement
When installing an OS, starting system, or
applying Standard Program Package
This event does not affect system operation.
4367
Agentless Management
Service
Error
Description of IML Event ID 4367, Class Code 17, Event Code 10:
xxxxx Connectivity status changed to Link Failure for adapter in slot
x, port xIf the connection is lost, then check the physical connection
from the server to its destination device such as interconnect,
blade, switch etc, including any cables. Refer to the NIC issues
flowchart in the Troubleshooting Guide for more information.
When installing an OS, starting system, or
applying Standard Program Package
This event does not affect system operation.
7000
Service Control Manager
Error
QLogic Fibre Channel Service service failed to start due to
the following error:
the system cannot find the file specified
Applying Standard Program Package
This event does not affect system operation.
37130
ESMCommonService
Error
Date : YYYY-MM-DD hh:mm:ss
Event Class : 0x11
Event Code : 0x0A
Status : Critical
Description : xxxxx Connectivity status changed to xxxxx
for adapter in slot x, port x
When starting system,
or applying Standard Program Package
This event does not affect system operation.
37132
ESMCommonService
Error
Date : YYYY-MM-DD hh:mm:ss
Event Class : 0x11
Event Code : 0x0C
Status : Critical
Description : Redundancy status changed to xxxxx by adapter
in slot x, port x
When starting system,
or applying Standard Program Package
This event does not affect system operation.
37133
ESMCommonService
Error
Date : YYYY-MM-DD hh:mm:ss
Event Class : 0x11
Event Code : 0x0D
Status : Critical
Description : All links are down in adapter xxxxx in slot x
When starting system,
or applying Standard Program Package
This event does not affect system operation.