5. Troubleshooting
Express5800/R120g-2E, T120g Maintenance Guide
39
Chapter 1 Maintenance
[?]
Event ID510: The following event to prompt battery refresh is logged if additionally battery for RAID
Controller has not been refreshed for about 1 year from beginning of use. (W, X: Number of RAID
Controller)
Event source : raidsrv
Event ID
: 510
Type :
Warning
Description : [CTRL: W (ID=X)]
Battery needs to be refreshed.
→
Additional battery for RAID controller is not refreshed automatically except for the first time. However, it
is recommended to perform battery refresh once a year as guideline for stable operation of battery. Use
Universal RAID Utility to perform battery refresh manually. See
Universal RAID Utility User's Guide
in
EXPRESSBUILDER for more information.
[?]
DISK LED flashes
Does DISK LED flash frequently even while the hard disk drive is not accessed?
→
Ignore the flashing. When Patrol Read is running, the DISK LED flashes even if the hard disk drive is not
being accessed. If a SATA hard disk drive is used, the DISK LED stays on.
Содержание Express5800/R120g