2. List of Windows Event Logs
Express5800/R120g-2E, T120g Maintenance Guide
215
Chapter 3 Appendix
Application Event Log
24
Microsoft-Windows-WM
I
Error
Event provider MLNXProvider attempted to register query "select * from
MLNX_NetAdapterStatusEvent" whose target class
"MLNX_NetAdapterStatusEvent" in //./root/standardcimv2/mlnx
namespace does not exist. The query will be ignored.
* There may be cases that the above message is somewhat different.
At the time of applying Starter Pack
This event is logged in the system when InfiniBand Adapter is
connected.
This event does not affect the system operation.
1014
Microsoft-Windows-
Security-SPP
Error
Failed to obtain end-user license.
hr=0x80072EE7
When installing an OS
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
1015
Microsoft-Windows-
Security-SPP
Warning
Detailed information of HRESULT
Returned hr=0xC004F022, original hr=0x80049E00
When installing an OS
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
1058
Microsoft-Windows-
Security-SPP
Error
Failed to obtain certificate of purchase from ACPI table.
Error code: 0xC004F057
When installing an OS
This event does not affect system operation.
1534
Microsoft-Windows-
User Profiles Service
Warning
Profile notification of event Create for component
{2c86c843-77ae-4284-9722-27d65366543c} failed.
When installing an OS
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
8198
Microsoft-Windows-
Security-SPP
Error
License Activation (slui.exe) failed with the following error code:
Error code: hr=0xC004F063
When installing an OS
Unless this event is not logged after license authentication, there is no
problem in system operation.
8200
Microsoft-Windows-
Security-SPP
Error
Detailed information about failure of license authentication
hr=0x80072EE7
When installing an OS
Unless this event is not logged repeatedly after license authentication,
there is no problem in system operation.
Applications and Services Logs
200
Microsoft-Windows-
DeviceSetupManager
Warning
A connection to the Windows Update Services could not be
established.
When running the system
If this event is not registered after the Internet connection is
established, there is no problem in system operation.
201
Microsoft-Windows-
DeviceSetupManager
Warning
A connection to the Windows Metadata and Internet Services (WMIS)
could not be established.
When running the system
If this event is not registered after the Internet connection is
established, there is no problem in system operation.
202
Microsoft-Windows-
DeviceSetupManager
Warning
The Network List Manager reports no connectivity to the internet.
When running the system
If this event is not registered after the Internet connection is
established, there is no problem in system operation.
Содержание Express5800/R120g