background image

 

-Memo- 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

● For Inquiries 

If you have any questions on this document, please contact your sales representative. 

 

 

 

 

 

 

Oct, 2015 

*855-911175-031-02R*

Содержание Express5800/R120f-1E

Страница 1: ...r Power Control Configuration Standby Power Save Enabled Enabled OS POWER ON 2 30 2 60 BIOS Standby Power Save Disabled BIOS SETUP Server Power Measurement Policy One Time Save Exit Save Changes and E...

Страница 2: ...uster On Die DIMM 1 CPU1_DIMM1 2 CPU1_DIMM1 CPU1_DIMM2 3 CPU1_DIMM1 CPU1_DIMM3 4 CPU1_DIMM1 CPU1_DIMM4 5 CPU1_DIMM1 CPU1_DIMM5 6 CPU1_DIMM1 CPU1_DIMM6 7 CPU1_DIMM1 CPU1_DIMM7 8 CPU1_DIMM1 CPU1_DIMM8 1...

Страница 3: ...ring Lockstep DIMM Cluster On Die DIMM 4 CPU1_DIMM1 CPU1_DIMM2 CPU2_DIMM1 CPU2_DIMM2 6 CPU1_DIMM1 CPU1_DIMM4 CPU2_DIMM1 CPU2_DIMM2 8 CPU1_DIMM1 CPU1_DIMM4 CPU2_DIMM1 CPU2_DIMM4 10 CPU1_DIMM1 CPU1_DIMM...

Страница 4: ...5 7 2 STATUS STATUS 1 2 STATUS 1 STATUS 2 BMC BMC CPU OFF OFF ON POST POST DUMP POST DUMP CPU PCI PCI PCI RAID0 RAID CPU SMI Timeout EXPRESSSCOPE 3...

Страница 5: ...86_64 Enabled UEFI VMware ESXi 6 Disabled Legacy 2 Linux Linux OS Red Hat R Enterprise Linux R 7 Server Red Hat R Enterprise Linux R 7 Server x86_64 1 1 11 1 OS OS Red Hat R Enterprise Linux R 7 x86_6...

Страница 6: ...Server x86 Red Hat R Enterprise Linux R 7 Server x86_64 P 63 P 94 Red Hat R Enterprise Linux R 7 x86_64 P 115 Red Hat Enterprise Linux 7 1 x86_64 P 217 P 218 Red Hat R Enterprise Linux R 6 Red Hat R...

Страница 7: ...and connect the power code two codes when installing a redundant power supply unit again After 60 seconds the server will start automatically Run BIOS Setup Utility and change the Standby Power Save...

Страница 8: ...2 for DIMM installation order The Cluster On Die feature could be enabled as below In 1 CPU configuration Memory RAS Mode Independent DIMMs count Cluster On Die feature DIMM Slot number to be installe...

Страница 9: ...ailable From CPU1_DIMM1 to CPU1_DIMM4 from CPU2_DIMM1 to CPU2_DIMM2 8 DIMMs Available recommended From CPU1_DIMM1 to CPU1_DIMM4 from CPU2_DIMM1 to CPU2_DIMM4 10 DIMMs Available From CPU1_DIMM1 to CPU1...

Страница 10: ...tact to the maintenance service company POST is in progress Memory dump is being requested e g when DUMP Switch is pressed Note Dump by Software makes LED color green CPU is not recognized WDT Watchdo...

Страница 11: ...4 Enable or disable the Cluster On Die feature This option is available when Enabled is selected for NUMA and the installed processor supports this feature Note If you are using VMware ESXi 5 5 Update...

Страница 12: ...Memo For Inquiries If you have any questions on this document please contact your sales representative Oct 2015 855 911175 031 02R...

Отзывы: