background image

 

■  Errata 

 

● About User’s Guide 

 

Chapter 4. Names and Function of Parts -> 4.7.2  Status LED1,2 

Table is revised as follows. 

 

STATUS ランプ 1,2 pattern 

Description 

Solution 

STATUS 

LED 1 

STATUS 

LED 2 

On(green) 

Off 

The server is operating normally. 

- 

On(green) 

On(amber) 

Initialization of BMC is in progress. 

Wait  until  the  initialization  is 
completed (LED off). 
If STATUS LEDs is not changed after some 
minutes, 

please 

contact 

to 

the 

maintenance service company. 

Flashing 
(green) 

Off 

Memory is in a degraded state. 

Check the power cord such as power supply 
route. 
If there is no problem, please contact the 
maintenance service company. 

Operating under CPU error. 
In redundant power unit configuration, power 
is not supplied to either of power unit. 

Off 

Off 

The power is off. 

If the power is OFF, please turn ON the 
power.  
If during POST, please wait until POST 
completion. 
If DUMP switch is pressed, please wait 
until the memory dump is completed. 
If  any  above  case  is  matched,  please 
contact  to  the  maintenance  service 
company. 

POST is in progress. 
Memory dump is being requested. 
(e.g. when DUMP Switch is pressed) 
Note: Dump by Software makes LED color green. 
CPU is not recognized. 
WDT (Watchdog timer timeout) is detected. 
Memory uncorrectable error is detected. 
PCI system error is detected. 
PCI parity error is detected. 
PCI bus error is detected. 

Off 

Flashing 
(amber) 

Temperature warning is detected. 

Clean the dust at the air inlet and FAN.
If LED is not changed after clean, please 
contact  to  the  maintenance  service 
company. 

Fan warning is detected. 
Voltage warning is detected. 
Power  Supply  Unit  failure  is  detected  (in 

power redundant configuration). 

One or more hard disk drive failure is detected  
(excluding RAID 0 or non-RAID configuration).
Log  collection  Stop:  (Memory  multiple 
recoverable error is detected.) 

Off 

On(amber) 

Power unit critical error is detected. 
Temperature critical error is detected. 
Voltage critical error is detected. 
CPU error is detected. 
Chipset error is detected. 
Memory uncorrectable error is detected. 
SMI timeout is detected. 
Sensor failure is detected. 
Intel Node Manager (EXPRESSSCCOPE Engine 3’s 
feature) error is detected. 

 
 
 
 
 
 
 
 
 

Содержание Express5800/R120f-1E

Страница 1: ...r Power Control Configuration Standby Power Save Enabled Enabled OS POWER ON 2 30 2 60 BIOS Standby Power Save Disabled BIOS SETUP Server Power Measurement Policy One Time Save Exit Save Changes and E...

Страница 2: ...uster On Die DIMM 1 CPU1_DIMM1 2 CPU1_DIMM1 CPU1_DIMM2 3 CPU1_DIMM1 CPU1_DIMM3 4 CPU1_DIMM1 CPU1_DIMM4 5 CPU1_DIMM1 CPU1_DIMM5 6 CPU1_DIMM1 CPU1_DIMM6 7 CPU1_DIMM1 CPU1_DIMM7 8 CPU1_DIMM1 CPU1_DIMM8 1...

Страница 3: ...ring Lockstep DIMM Cluster On Die DIMM 4 CPU1_DIMM1 CPU1_DIMM2 CPU2_DIMM1 CPU2_DIMM2 6 CPU1_DIMM1 CPU1_DIMM4 CPU2_DIMM1 CPU2_DIMM2 8 CPU1_DIMM1 CPU1_DIMM4 CPU2_DIMM1 CPU2_DIMM4 10 CPU1_DIMM1 CPU1_DIMM...

Страница 4: ...5 7 2 STATUS STATUS 1 2 STATUS 1 STATUS 2 BMC BMC CPU OFF OFF ON POST POST DUMP POST DUMP CPU PCI PCI PCI RAID0 RAID CPU SMI Timeout EXPRESSSCOPE 3...

Страница 5: ...86_64 Enabled UEFI VMware ESXi 6 Disabled Legacy 2 Linux Linux OS Red Hat R Enterprise Linux R 7 Server Red Hat R Enterprise Linux R 7 Server x86_64 1 1 11 1 OS OS Red Hat R Enterprise Linux R 7 x86_6...

Страница 6: ...Server x86 Red Hat R Enterprise Linux R 7 Server x86_64 P 63 P 94 Red Hat R Enterprise Linux R 7 x86_64 P 115 Red Hat Enterprise Linux 7 1 x86_64 P 217 P 218 Red Hat R Enterprise Linux R 6 Red Hat R...

Страница 7: ...and connect the power code two codes when installing a redundant power supply unit again After 60 seconds the server will start automatically Run BIOS Setup Utility and change the Standby Power Save...

Страница 8: ...2 for DIMM installation order The Cluster On Die feature could be enabled as below In 1 CPU configuration Memory RAS Mode Independent DIMMs count Cluster On Die feature DIMM Slot number to be installe...

Страница 9: ...ailable From CPU1_DIMM1 to CPU1_DIMM4 from CPU2_DIMM1 to CPU2_DIMM2 8 DIMMs Available recommended From CPU1_DIMM1 to CPU1_DIMM4 from CPU2_DIMM1 to CPU2_DIMM4 10 DIMMs Available From CPU1_DIMM1 to CPU1...

Страница 10: ...tact to the maintenance service company POST is in progress Memory dump is being requested e g when DUMP Switch is pressed Note Dump by Software makes LED color green CPU is not recognized WDT Watchdo...

Страница 11: ...4 Enable or disable the Cluster On Die feature This option is available when Enabled is selected for NUMA and the installed processor supports this feature Note If you are using VMware ESXi 5 5 Update...

Страница 12: ...Memo For Inquiries If you have any questions on this document please contact your sales representative Oct 2015 855 911175 031 02R...