■ Errata
● About User’s Guide
Chapter 4. Names and Function of Parts -> 4.7.2 Status LED1,2
Table is revised as follows.
STATUS ランプ 1,2 pattern
Description
Solution
STATUS
LED 1
STATUS
LED 2
On(green)
Off
The server is operating normally.
-
On(green)
On(amber)
Initialization of BMC is in progress.
Wait until the initialization is
completed (LED off).
If STATUS LEDs is not changed after some
minutes,
please
contact
to
the
maintenance service company.
Flashing
(green)
Off
Memory is in a degraded state.
Check the power cord such as power supply
route.
If there is no problem, please contact the
maintenance service company.
Operating under CPU error.
In redundant power unit configuration, power
is not supplied to either of power unit.
Off
Off
The power is off.
If the power is OFF, please turn ON the
power.
If during POST, please wait until POST
completion.
If DUMP switch is pressed, please wait
until the memory dump is completed.
If any above case is matched, please
contact to the maintenance service
company.
POST is in progress.
Memory dump is being requested.
(e.g. when DUMP Switch is pressed)
Note: Dump by Software makes LED color green.
CPU is not recognized.
WDT (Watchdog timer timeout) is detected.
Memory uncorrectable error is detected.
PCI system error is detected.
PCI parity error is detected.
PCI bus error is detected.
Off
Flashing
(amber)
Temperature warning is detected.
Clean the dust at the air inlet and FAN.
If LED is not changed after clean, please
contact to the maintenance service
company.
Fan warning is detected.
Voltage warning is detected.
Power Supply Unit failure is detected (in
power redundant configuration).
One or more hard disk drive failure is detected
(excluding RAID 0 or non-RAID configuration).
Log collection Stop: (Memory multiple
recoverable error is detected.)
Off
On(amber)
Power unit critical error is detected.
Temperature critical error is detected.
Voltage critical error is detected.
CPU error is detected.
Chipset error is detected.
Memory uncorrectable error is detected.
SMI timeout is detected.
Sensor failure is detected.
Intel Node Manager (EXPRESSSCCOPE Engine 3’s
feature) error is detected.