8-46 Troubleshooting
T
This message may be logged when SAS hard disk drive that has not been configured
is removed from the slot.
→
It is not a problem in operating the system.
T
If the message is displayed again for the specific hard disk drive, check if the hard
disk drive is connected correctly.
→
If the same error message appears repeatedly, contact your service representative
to replace the hard disk drive.
There are some cases that an event log is registered in MegaRAID Storage Manager (MSM) log
at startup of OS after rebuilding the hard disk drives with WebBIOS.
Controller ID:x VD is now DEGRADED VD x.
→
It is not a problem in operating the system.
A popup message may appear if the notification feature for NEC ESMPRO
Manager is enabled.
There are some cases that an event log is registered in application log of the Event Viewer at
startup of OS after rebuilding the hard disk drives with WebBIOS.
Event Source: MR_MONITOR
Event Type:
Error
Event ID:
251
Description: Controller ID:x VD is now DEGRADED VD x.
→
It is not a problem in operating the system.
A popup message may appear if the notification feature for NEC ESMPRO
Manager is enabled.
Содержание Express5800/140Re-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 38: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Страница 76: ...2 38 General Description This page is intentionally left blank ...
Страница 187: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed ...
Страница 494: ...F 4 Product Configuration Record Table This page is intentionally left blank ...