2-2 Overview
SPECIFICATIONS
The table below lists the general specifications of the unit.
Major
classification
Minor
classification
Standard Remarks
Power supply
Single phase, 2-pole grounding
Voltage
100 to 240 VAC
±
10%
Frequency
50
±
1 Hz or 60
±
1 Hz
Input power
Waveform
distortion
10%
The power supply itself
is capable between 100
to 240 VAC, however,
the value at the left is
used as a unit
specification.
Input current
5.3 A
Apparent power 530 VA
Power
consumption
Active power
520 W
AC100V
Temperature
10 to 35
o
C
Temperature and
humidity
Humidity
20 to 80%RH
No condensation is
allowed
POWER level
62.8 dB (operating)
60.9 dB (standby)
Noise
Sound pressure
level
52.9 dB (operating)
51.7 dB (standby)