BMC Configuration User’s Guide
Item
Description
Default Value
Cooling
Cooling function setting
BBU(*1) on PCI Slot
Select the cooling function of the BBU(*1).
Not -Installed
Installed
Not -Installed
Fault Handling
Fault Handling function setting
Degraded Server Boot
Policy
Select the Degraded Server Boot Policy.
Boot
Not-Boot
Not-Boot
Failing Unit Removal
Select Enable/Disable of Failing Unit Removal.
Enable
Disable
Enable
FRB2 Monitoring
Select Enable/Disable of FRB2 Monitoring.
Enable
Disable
Enable
POST Monitoring *3
Select Enable/Disable of POST Monitoring.
Enable
Disable
Enable
Boot Monitoring *3
Select Enable/Disable of Boot Monitoring.
Enable (Set time [Min])
Disable
Disable
OpROM Monitoring *3
Select Enable/Disable of OpROM Monitoring.
Enable
Disable
Disable
Failure Flow Monitoring *3
Select Enable/Disable of Failure Flow Monitoring.
Enable (Set time [Min])
Disable
Disable
Shutdown Monitoring *3
Select Enable/Disable of Shutdown Monitoring.
Enable (Set time [Min])
Disable
Disable
Diagnostics *2
Diagnostics function setting
Periodic Diagnosis
Select Enable/Disable of Periodic Diagnosis.
Enable
Disable
Enable
Configuration *2
Various other setting
Master Clock Module
Select the Master Clock Module.
Clock1
Clock2
Clock1
Spare Memory Configuration
Mode
Select the Spare Memory Configuration Mode.
Static
Dynamic
Static
Spare PCIe Configuration
Mode
Select the Spare PCIe Configuration Mode.
Static
Dynamic
Static
*1: Battery Backup Unit for SAS Card
*2: It is not displayed when the system does not support this function.
*3: This item only exists in Off-line TOOL. It is displayed when the system supports this function.
CHECK:
This setting is applied at the next booting time of the managed server.
Содержание Express 5800 Series
Страница 32: ...BMC Configuration User s Guide 4 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 71: ...BMC Configuration User s Guide 5 2 8 Mail Alert This screen displays and sets the alert by E mail from BMC...
Страница 73: ...BMC Configuration User s Guide 5 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 90: ...BMC Configuration User s Guide BMC Configuration User s Guide NEC Corporation 2011 2015...