BMC Configuration User’s Guide
Item
Description
Default Value
SNMP Alert
SNMP Alert setting
Alert*1
Select Enable/Disable of SNMP Alert.
Disable
Computer Name
Set the Computer Name. *2
Blank
Community Name
Set the Community Name. *2
public
Alert Process
Select One Alert Receiver/All Alert Receiver of Alert
Process.
One Alert Receiver
Alert Acknowledge
Select Enable/Disable of Alert Acknowledge.
Enable
Alert Retry Count
Set the count of Alert retry. *3
3
Alert Timeout
Set the seconds to alert timeout. *3
6
Alert Receiver
Alert Receiver setting.
Primary IP Address
Select Enable/Disable of Primary IP Address. *4
Enable
IP Address
Set the IP Address of Primary. *5
0.0.0.0
Secondary IP Address
Select Enable/Disable of Secondary IP Address. *4
Disable
IP Address
Set the IP Address of Secondary. *5
0.0.0.0
Tertiary IP Address
Select Enable/Disable of Tertiary IP Address. *4
Disable
IP Address
Set the IP Address of Tertiary. *5
0.0.0.0
Alert Level
Alert Level setting
Alert Level
Set the kind of event to alert. *6
Error/ Warning
Alert Test
Execute the alert test by SNMP.
*1: When PEF(Platform Event Filter) setting is "Disable", it can not alert.
*2: It is possible to set less than 16 half-size alphanumeric characters.
*3: It is possible to set when Alert Acknowledge is "Enable".
*4: When SNMP Alert is enabled, one or more of the addresses should be enable.
*5: It is possible to set when each Alert Receiver is"Enable".
*6: The Alert Level are as follows:
Alert Level
Description
Error
When "Error" is detected in each sensor type, the alert is sent to the checked
address.
Error/ Warning
When "Error" or "Warning" is detected in each sensor type, the alert is sent to
the checked address.
Error/ Warning/ Information When "Error", "Warning" or "Information" is detected in each sensor type, the
alert is sent to the checked address.
Separate Setting
You can arbitrarily select the event to alert in each sensor type.
Содержание Express 5800 Series
Страница 32: ...BMC Configuration User s Guide 4 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 71: ...BMC Configuration User s Guide 5 2 8 Mail Alert This screen displays and sets the alert by E mail from BMC...
Страница 73: ...BMC Configuration User s Guide 5 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 90: ...BMC Configuration User s Guide BMC Configuration User s Guide NEC Corporation 2011 2015...