BMC Configuration User’s Guide
*1: It is possible to set when the system supports change.
*2: If you modify this setting, "Reset BMC" is necessary on some systems. When set to "Shared BMC LAN",
the management LAN port is disabled. When set to "Shared BMC LAN", the network performance may be
reduced because the data of both LANs must be transmitted or received.
*3: When the Subnet Mask is wrong setting, error message, such as "Failed to apply configuration.", is
displayed.
*4: It is possible to set when DHCP is "Disable".
*5: It is possible to set when DHCP is "Enable".
*6: The length of Host Name must be less than 64 characters. Host Name will be truncated to 63 characters,
if you input over 63 characters.
*7: Host Name and Domain Name should be within total of 255 characters.
*8: The range of IP address to "Allow" or "Deny" access is delimited by ",(Comma)". With regard to the
setting of “Deny” access, "*(Asterisk)" can be described as a wild-card. (ex:
192.168.1.*,192.168.2.1,192.168.2.254)
*9: It is possible to set when Access Limitation Type is "Allowed Address" or "Denied Address". The length
must be less than 255 characters.
*10: It is possible to set or display in the case of EXPRESSSCOPE Engine SP3.
*11: The default value is "192.168.1.100" or "192.168.1.101" in the case of EXPRESSSCOPE Engine SP3.
*12: It displays only the case of Network(Master) of EXPRESSSCOPE Engine SP3.
Содержание Express 5800 Series
Страница 32: ...BMC Configuration User s Guide 4 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 71: ...BMC Configuration User s Guide 5 2 8 Mail Alert This screen displays and sets the alert by E mail from BMC...
Страница 73: ...BMC Configuration User s Guide 5 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 90: ...BMC Configuration User s Guide BMC Configuration User s Guide NEC Corporation 2011 2015...