BMC Configuration User’s Guide
Item
Description
Default Value
Authentication Key
Set the Authentication Key. *6 *7
guest
Redirection
Select Enable/Disable of Redirection. *6
If Redirection is set to "Enable", BIOS Redirection Port in
Console Redirection Configuration of BIOS is set to "Serial
Port B".
Enable
*1: When this item is changed to/from "Overwrite oldest SEL", all log records in the SEL Repository are
cleared.
*2: When the "Standby Power Save" function of System BIOS is Enable, it is set to "Power On". And the
default value is changed to "Power On".
*3: It is not possible to set when AC-Link is "Stay Off" or the system is Blade Server. Delay time from
turning on AC to turning on DC is specified. It is possible to set up to 600(seconds). Minimum value is
different according to the system. It is possible to set "Random" when the system supports it.
*4: "Enable" and "Disable" of the report function from BMC are set. It makes SNMP Alert be impossible
when it sets to "Disable".
*5: When BMC can be managed directly from NEC ESMPRO Manager (Ver.5.4 or later), it must be set to
"Enable". If it sets to "Enable", Authentication Key also must be set.
*6: It is possible to set when NEC ESMPRO Management is set "Enable".
*7: It is Authentication key when managing from NEC ESMPRO Manager (Ver.5.4 or later). It is possible to
set less than 16 half-size alphanumeric characters.
CHECK:
Power Restore Delay settings do not exist in Off-line TOOL.
Содержание Express 5800 Series
Страница 32: ...BMC Configuration User s Guide 4 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 71: ...BMC Configuration User s Guide 5 2 8 Mail Alert This screen displays and sets the alert by E mail from BMC...
Страница 73: ...BMC Configuration User s Guide 5 2 9 SNMP Alert This screen displays and sets the alert by SNMP from BMC...
Страница 90: ...BMC Configuration User s Guide BMC Configuration User s Guide NEC Corporation 2011 2015...