Disassembly and Reassembly
Non-Hot-Swap Power Supply
Your server system may contain a single non-hot-swap power supply that is
housed in the rear of the chassis as shown in Figure 4-33.
Removal
1.
Prepare your system for disassembly. See
Preparing Your System for
Disassembly and Reassembly
earlier in this chapter.
2.
Remove the left-hand side access panel of the system chassis. See
Removing
the Side Access Panel
earlier in this chapter.
!
CAUTION
For proper cooling and airflow, do not operate the system
with the side access panel removed. Always
replace
the
panel before powering on the system.
3.
Remove all the power cables from the system board, 5.25-inch devices,
diskette drive, and SCSI backplane.
4.
Remove and save the nine screws that secure the power supply to the rear of
the chassis. See Figure 4-33.
A
A
A
Figure 4-33. Removing the Non-Hot-Swap Power Supply
5.
Carefully remove the power supply from the chassis.
6.
Follow this removal procedure in reverse order to install the replacement
power supply unit.
Содержание Express 5800/120Lg
Страница 1: ... S e r v i c e G u i d e EXPRESS5800 120Lg ...
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 73: ...Disassembly and Reassembly 4 7 Figure 4 2 Installing the Left Hand Side Access Panel ...
Страница 132: ......
Страница 161: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units ...
Страница 168: ......
Страница 169: ...A Specifications System Specifications ...
Страница 179: ...C IRQ and I O Port Addresses Interrupt Requests PIRQ and PCI Device ...
Страница 188: ......
Страница 198: ......
Страница 203: ...xx ...
Страница 204: ... 456 01673 000 ...