Issue 6
Electra Elite
2 - 8
System Specifications
4.2
Cabling Precautions
4.2.1
Cable Placement
When selecting cables and Main Distribution Frame
(MDF), future expansion or assignment changes should
be considered. Avoid running cables in the following
places:
A place exposed to wind or rain.
A place near heat radiating equipment or where the
quality of station cable covering could be affected
by gases and chemicals.
An unstable place subject to vibration.
4.2.2
Environmental Conditions
Temperature
Operating:
+32°F ~ +104°F (0°C ~ 40°C)
Long Term:
+50°F ~ +90°F (10°C ~ 32.2°C)
Humidity
Operating:
10% ~ 90% noncondensing
4.3
Power Requirements
4.3.1
Power Supply Inputs
AC input requirements for the system are listed below.
AC Input (P64-U10 PSU)
117 Vac ± 10%
60 Hz ± 10%
Single Phase
7.5A circuit
A dedicated outlet, separately fused and grounded
Table 2-7 Zone Transceiver II Range
Connected Equipment
Range
ZT II-U Unit without ACA-U Unit
3,000 feet
ZT II-U Unit with ACA-U Unit
16,404 feet
Содержание Electra Elite 192
Страница 2: ...SYSTEM HARDWARE MANUAL Stock Number 750363 Issue 6 Series 6000 192 ...
Страница 3: ......
Страница 5: ......
Страница 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 10: ...Regulatory Information ...
Страница 11: ......
Страница 20: ......
Страница 52: ...Issue 6 Electra Elite xxxii List of Tables THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 73: ...Electra Elite Issue 6 System Hardware Manual 1 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 74: ...Issue 6 Electra Elite 1 22 Introduction ...
Страница 92: ...Issue 6 Electra Elite 2 18 System Specifications Output Impedance 600 Ω Relay Contact Rating 500 mA 24 Vdc ...
Страница 96: ...Issue 6 Electra Elite 2 22 System Specifications ...
Страница 104: ...Issue 6 Electra Elite 3 8 Hardware Requirements THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 213: ...Electra Elite Issue 6 System Hardware Manual 5 67 Figure 5 39 FMS 8 U10 ETU ...
Страница 252: ...Issue 6 Electra Elite 5 106 Installing Electronic Telephone Units THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 282: ...Issue 6 Electra Elite 6 30 Installing Electra Elite Multiline Terminals THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 336: ...Issue 6 Electra Elite 7 54 Installing Optional Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 342: ...Issue 6 Electra Elite 8 6 Installing Electra Professional Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 368: ...Issue 6 Electra Elite A 4 Glossary of Abbreviations THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 369: ...SYSTEM HARDWARE MANUAL NEC America Inc Issue 6 Series 6000 192 ...