UNIVERGE SV8100
Issue 5.0
General Description Manual
5 - 15
S
ECTION
2
C
HASSIS
P
OWER
B
ASED
C
ALCULATOR
C
HART
The Univerge SV8100 system uses two types of power factors. For a single chassis
chart refer to
Table 5-8 Board Power Factor
. For the maximum number of specific
blades per package, see
Table 5-9 Maximum Number of Packages Installed
. Refer to
Table 5-10 Terminal Power Factor on page 5-16
for the Terminal/ Adapter power
chart.
Table 5-8 Board Power Factor
Board Power Factor
Total =<7
Item
Power Factor
CD-CP00-US
1
CD-RTB
2
CD-VM00
2
CD-ETIA
2
CD-PVAA
1
PZ-32IPLA
1
PZ-64IPLA
2
PZ-128IPLA
2
Table 5-9 Maximum Number of Packages Installed
Board
(Power Factor)
Maximum Number of Package Installed
9.5 inch
with CCPU
19 inch
with CCPU
19 inch
without
CCPU
4 x 19 inch
CD-ETIA (2)
2
3
3
12
CD-PVAA (1)
2
5
6
23
CD-RTB (2)
1
2
2
8